Test–retest reliability of skeletal muscle oxygenation measurements during submaximal cycling exercise in patients with chronic heart failure

V.M. Niemeijer, R.F. Spee, J.P. Jansen, A.B.C. Buskermolen, T. van Dijk, P.F.F. Wijn, H.M.C. Kemps

Research output: Contribution to journalArticleAcademicpeer-review

18 Citations (Scopus)

Abstract

The potential purpose of near-infrared spectroscopy (NIRS) as a clinical application in patients with chronic heart failure (CHF) is the identification of limitations in O2 delivery or utilization during exercise. The objective of this study was to evaluate absolute and relative test–retest reliability of skeletal muscle oxygenation measurements in patients with CHF. Thirty patients with systolic heart failure (left ventricular ejection fraction 31 ± 8%) performed 6-min constant-load cycling tests at 80% of the anaerobic threshold (AT) with tissue saturation index (TSI) measurement at the vastus lateralis. Tests were repeated after 10 ± 5 days to evaluate reliability. Absolute reliability was assessed with limits of agreement (LoA, expressed as bias ± random error) and coefficients of variation (CV) for absolute values (LoA range: 0·4 ± 6·2% to 0·6 ± 7·9%; CV range: 4·7–7·1%), amplitudes (LoA range −0·5 ± 5·8% to −0·7 ± 6·8%; CV range: 26·2–42·1%), onset and recovery kinetics (mean response times; LoA 0·4 ± 9·5 s, CV 23·5% and LoA −5·8 ± 50·8 s, CV 67·4% respectively) and overshoot characteristics (CV range 45·7–208·6%). Relative reliability was assessed with intraclass correlation coefficients for absolute values (range 0·74–0·90), amplitudes (range 0·85–0·92), onset and recovery kinetics (0·53 and 0·51, respectively) and overshoot characteristics (range 0·17–0·74). In conclusion, absolute reliability of absolute values and onset kinetics seems acceptable for serial within-subject comparison, and as such, for evaluation of treatment effects. Absolute reliability of amplitudes and recovery kinetics is considered unsatisfactory. Relative reliability of absolute values and amplitudes is sufficient for purposes of physiological distinction between patients with CHF. Despite lower relative reliability, kinetics may still be useful for clinical application.

Original languageEnglish
Pages (from-to)68-78
Number of pages11
JournalClinical Physiology and Functional Imaging
Volume37
Issue number1
DOIs
Publication statusPublished - 1 Jan 2017

Keywords

  • heart failure
  • intraclass correlation coefficient
  • limits of agreement
  • near-infrared spectroscopy
  • repeatability
  • reproducibility
  • Predictive Value of Tests
  • Ventricular Function, Left
  • Humans
  • Middle Aged
  • Muscle, Skeletal/blood supply
  • Male
  • Anaerobic Threshold
  • Recovery of Function
  • Exercise Test
  • Heart Failure/diagnosis
  • Spectroscopy, Near-Infrared
  • Biomarkers/blood
  • Female
  • Exercise Therapy/methods
  • Cardiac Rehabilitation/methods
  • Reproducibility of Results
  • Oxygen Consumption
  • Treatment Outcome
  • Stroke Volume
  • Bicycling
  • Aged
  • Kinetics
  • Oxygen/blood

Fingerprint

Dive into the research topics of 'Test–retest reliability of skeletal muscle oxygenation measurements during submaximal cycling exercise in patients with chronic heart failure'. Together they form a unique fingerprint.

Cite this