Statistical time lags in ac discharges

A. Sobota, J.H.M. Kanters, E.M. Veldhuizen, van, F. Manders, M. Haverlag

Research output: Contribution to journalArticleAcademicpeer-review

12 Citations (Scopus)
1 Downloads (Pure)

Abstract

The paper presents statistical time lags measured for breakdown events in near-atmospheric pressure argon and xenon. Ac voltage at 100, 400 and 800 kHz was used to drive the breakdown processes, and the voltage amplitude slope was varied between 10 and 1280 V ms-1. The values obtained for the statistical time lags are roughly between 1 and 150 ms. It is shown that the statistical time lags in ac-driven discharges follow the same general trends as the discharges driven by voltage of monotonic slope. In addition, the validity of the Cobine–Easton expression is tested at an alternating voltage form.
Original languageEnglish
Article number135203
Pages (from-to)135203-1/
Number of pages9
JournalJournal of Physics D: Applied Physics
Volume44
Issue number13
DOIs
Publication statusPublished - 2011