Abstract
Many steel rope systems are subjected to fluctuating tensile loads and therefore can fail due to fatigue. There are indications that the fatigue resistance of full-locked coil ropes is somewhat lower than that of other types of rope. Fatigue test data on full-locked coil ropes have been collected, but they terminate at different conditions. A semi-empirical model is employed to extrapolate the test results to full failure of the rope. The resulting S-N curve is being adopted for the revision of European standard prEN 1993-1-11.
Original language | English |
---|---|
Pages (from-to) | 205-215 |
Number of pages | 11 |
Journal | Steel Construction : Design and Research |
Volume | 14 |
Issue number | 3 |
Early online date | 8 Jul 2021 |
DOIs | |
Publication status | Published - Aug 2021 |
Keywords
- Full-locked coil rope
- Fatigue tests
- Cable
- Strand
- Eurocode 3
- Masts and towers
- fatigue tests
- strand
- Cable and membrane structures
- full-locked coil rope
- cable
- Experiments