Skip to main navigation Skip to search Skip to main content

Releasing the circumferential fixation of the medial meniscus does not affect its kinematics

  • Anne Vrancken
  • , Tony George van Tienen
  • , G. Hannink
  • , Dennis Janssen
  • , N.J.J. Verdonschot
  • , P. Buma

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

BACKGROUND: Meniscal functioning depends on the fixation between the meniscal horns and the surrounding tissues. It is unknown, however, whether the integration between the outer circumference of the medial meniscus and the knee capsule/medial collateral ligament also influences the biomechanical behavior of the meniscus. Therefore, we aimed to determine whether detaching and resuturing the circumferential fixation of the medial meniscus influence its kinematic pattern.

METHODS: Human cadaveric knee joints were flexed (0°-30°-60°-90°) in a knee loading rig, in neutral orientation and under internal and external tibial torques. Roentgen stereophotogrammetric analysis was used to determine the motion of the meniscus in anteroposterior (AP) and mediolateral (ML) directions. Three fixation conditions were evaluated: (I) intact, (II) detached and (III) resutured.

RESULTS: Detaching and resuturing the circumferential fixation did not alter the meniscal motion pattern in either the AP or ML direction. Applying an additional internal tibial torque caused the medial meniscus to move slightly anteriorly, and an external torque caused a little posterior translation with respect to the neutral situation. These patterns did not change when the circumferential fixation condition was altered.

CONCLUSIONS: This study demonstrated that the motion pattern of the medial meniscus is independent of its fixation to the knee capsule and medial collateral ligament.

CLINICAL RELEVANCE: The outcomes of this study can be deployed to design the fixation strategy of a permanent meniscus prosthesis. As peripheral fixation is a complicated step during meniscal replacement, the surgical procedure is considerably simplified when non-resorbable implants do not require circumferential fixation.

Original languageEnglish
Pages (from-to)1033-1038
Number of pages6
JournalThe Knee
Volume21
Issue number6
DOIs
Publication statusPublished - Dec 2014

Keywords

  • Aged
  • Aged, 80 and over
  • Biomechanical Phenomena
  • Cadaver
  • Female
  • Humans
  • Joint Instability
  • Knee Joint
  • Male
  • Menisci, Tibial
  • Radiostereometric Analysis
  • Range of Motion, Articular

Fingerprint

Dive into the research topics of 'Releasing the circumferential fixation of the medial meniscus does not affect its kinematics'. Together they form a unique fingerprint.

Cite this