HIGH-VOLTAGE INSTALLATIONS ARE DESIGNED TO CARRY 50 Hz POWER. THE OFTEN LONG STRUCTURES ACT HOWEVER AS TRANSMISSION LINES FOR HIGHFREQUENCY PHENOMENA. TRAVELING WAVES AND REFLECTIONS AT ENDS CAN RESULT IN COMPLICATED TRANSIENT WAVE SHAPES. THE TRAVELING WAVES AND THE REFLECTIONS CAN ALSO BE USEFUL IN RESEARCH, TO ANALYZE CERTAIN PROBLEMS. AS EXAMPLES WE DESCRIBE TRAVELING WAVES CAUSED BY PARTIAL DISCHARGES IN A POWER CABLE; TRAVELING WAVES ON A 66 KM LONG OVERHEAD LINE UPON ENERGIZATION AND TRAVELING WAVES IN A GIS WITH AN ADDITIONAL 4M LONG CORONA SECTION.
Original languageEnglish
Pages (from-to)854-855
Number of pages2
JournalEnergietechniek
Volume71
Issue number12
Publication statusPublished - 1993

Fingerprint

Overhead lines
Geographic information systems
Electric lines
Cables
Electric potential

Cite this

Heesch, van, E.J.M. ; Laan, van der, P.C.T. ; Wouters, P.A.A.F. / Reflections in de energietechniek. In: Energietechniek. 1993 ; Vol. 71, No. 12. pp. 854-855.
@article{3e0afc22ca19406ba8cb3ac4c8a6d8ea,
title = "Reflections in de energietechniek",
abstract = "HIGH-VOLTAGE INSTALLATIONS ARE DESIGNED TO CARRY 50 Hz POWER. THE OFTEN LONG STRUCTURES ACT HOWEVER AS TRANSMISSION LINES FOR HIGHFREQUENCY PHENOMENA. TRAVELING WAVES AND REFLECTIONS AT ENDS CAN RESULT IN COMPLICATED TRANSIENT WAVE SHAPES. THE TRAVELING WAVES AND THE REFLECTIONS CAN ALSO BE USEFUL IN RESEARCH, TO ANALYZE CERTAIN PROBLEMS. AS EXAMPLES WE DESCRIBE TRAVELING WAVES CAUSED BY PARTIAL DISCHARGES IN A POWER CABLE; TRAVELING WAVES ON A 66 KM LONG OVERHEAD LINE UPON ENERGIZATION AND TRAVELING WAVES IN A GIS WITH AN ADDITIONAL 4M LONG CORONA SECTION.",
author = "{Heesch, van}, E.J.M. and {Laan, van der}, P.C.T. and P.A.A.F. Wouters",
year = "1993",
language = "English",
volume = "71",
pages = "854--855",
journal = "Energietechniek",
issn = "0927-6629",
number = "12",

}

Heesch, van, EJM, Laan, van der, PCT & Wouters, PAAF 1993, 'Reflections in de energietechniek', Energietechniek, vol. 71, no. 12, pp. 854-855.

Reflections in de energietechniek. / Heesch, van, E.J.M.; Laan, van der, P.C.T.; Wouters, P.A.A.F.

In: Energietechniek, Vol. 71, No. 12, 1993, p. 854-855.

Research output: Contribution to journalArticleProfessional

TY - JOUR

T1 - Reflections in de energietechniek

AU - Heesch, van, E.J.M.

AU - Laan, van der, P.C.T.

AU - Wouters, P.A.A.F.

PY - 1993

Y1 - 1993

N2 - HIGH-VOLTAGE INSTALLATIONS ARE DESIGNED TO CARRY 50 Hz POWER. THE OFTEN LONG STRUCTURES ACT HOWEVER AS TRANSMISSION LINES FOR HIGHFREQUENCY PHENOMENA. TRAVELING WAVES AND REFLECTIONS AT ENDS CAN RESULT IN COMPLICATED TRANSIENT WAVE SHAPES. THE TRAVELING WAVES AND THE REFLECTIONS CAN ALSO BE USEFUL IN RESEARCH, TO ANALYZE CERTAIN PROBLEMS. AS EXAMPLES WE DESCRIBE TRAVELING WAVES CAUSED BY PARTIAL DISCHARGES IN A POWER CABLE; TRAVELING WAVES ON A 66 KM LONG OVERHEAD LINE UPON ENERGIZATION AND TRAVELING WAVES IN A GIS WITH AN ADDITIONAL 4M LONG CORONA SECTION.

AB - HIGH-VOLTAGE INSTALLATIONS ARE DESIGNED TO CARRY 50 Hz POWER. THE OFTEN LONG STRUCTURES ACT HOWEVER AS TRANSMISSION LINES FOR HIGHFREQUENCY PHENOMENA. TRAVELING WAVES AND REFLECTIONS AT ENDS CAN RESULT IN COMPLICATED TRANSIENT WAVE SHAPES. THE TRAVELING WAVES AND THE REFLECTIONS CAN ALSO BE USEFUL IN RESEARCH, TO ANALYZE CERTAIN PROBLEMS. AS EXAMPLES WE DESCRIBE TRAVELING WAVES CAUSED BY PARTIAL DISCHARGES IN A POWER CABLE; TRAVELING WAVES ON A 66 KM LONG OVERHEAD LINE UPON ENERGIZATION AND TRAVELING WAVES IN A GIS WITH AN ADDITIONAL 4M LONG CORONA SECTION.

M3 - Article

VL - 71

SP - 854

EP - 855

JO - Energietechniek

JF - Energietechniek

SN - 0927-6629

IS - 12

ER -