Performance of different metrics proposed to CIE TC 1-91

P. Bhusal, R. Dangol

Research output: Contribution to journalArticleAcademicpeer-review

226 Downloads (Pure)

Abstract

The main aim of the article is to find out the performance of different metrics proposed to CIE TC 1-91. Currently, six different indexes have been proposed to CIE TC 1-91: Colour Quality Scale (CQS), Feeling of Contrast Index (FCI), Memory colour rendering index (MCRI), Preference of skin (PS), Relative gamut area index (RGAI) and Illuminating Engineering society Method for evaluating light source colour rendition (IES TM-30). The evaluation and analysis are based on previously conducted experiment in lighting booth. The analysis showed the area based metric FCI was good subjective preference indicator. The subjective preference was measured in terms of naturalness of objects, colourfulness of colour checker chart, and the visual appearance of the lit scene in the booth.
Original languageEnglish
Pages (from-to)91-103
Number of pages13
JournalInternational Journal of Sustainable Lighting
Volume19
Issue number2
DOIs
Publication statusPublished - 29 Dec 2017

Keywords

  • color quality, color rendering, LED light sources, colorimetry

Fingerprint

Dive into the research topics of 'Performance of different metrics proposed to CIE TC 1-91'. Together they form a unique fingerprint.

Cite this