T1 - Novel radiopaque ultrahigh molecular weight polyethylene sublaminar wires in a growth-guidance system for the treatment of early-onset scoliosis
T2 - feasibility in a large animal study
AU - Bogie, Rob
AU - Roth, A.K.
AU - de Faber, S.
AU - de Jong, J.J.A.
AU - Welting, T.J.M.
AU - Willems, P.C.
AU - Arts, J.J.C.
AU - van Rhijn, L.W.
PY - 2014/12/1
Y1 - 2014/12/1
N2 - STUDY DESIGN. In vivo analysis in an ovine model. OBJECTIVE. To evaluate the feasibility of radiopaque ultrahigh molecular weight polyethylene (UHMWPE) sublaminar wires in a growth-guidance spinal system by assessing stability, biocompatibility, and growth potential. SUMMARY OF BACKGROUND DATA. Several growth-guidance systems have been developed for the treatment of early-onset scoliosis. The use of gliding pedicle screws and metal sublaminar wires during these procedures can cause metal-on-metal debris formation and neurological deficits. Novel radiopaque UHMWPE wires are introduced to safely facilitate longitudinal growth and provide stability in a growth-guidance system for early-onset scoliosis. METHODS. Twelve immature sheep received posterior segmental spinal instrumentation; pedicle screws were inserted at L5 and radiopaque UHMWPE (bismuth trioxide) wires were passed sublaminarly at each level between L3 and T12 and fixed to dual cobalt-chromium rods. Four age-matched animals that were not operated were evaluated to serve as a control group. Radiographs were obtained to measure growth of the instrumented segment. After 24 weeks, the animals were killed and the spines were harvested for histological evaluation and high-resolution peripheral quantitative computed tomographic analysis. RESULTS. No neurological deficits occurred and all instrumentation remained stable. One animal died from an unknown cause. Substantial growth occurred in the instrumented segments (L5-T11) in the intervention group (27 ± 2 mm), which was not significantly different to the control group, (30 ± 4 mm, P = 0.42). High-resolution peripheral quantitative computed tomographic analysis clearly showed safe routing and fixation of the UHMWPE wires and instrumentation. Despite the noted growth, ectopic bone formation with the formation of bony bridges was observed in all animals. Histology revealed no evidence of chronic inflammation or wear debris. CONCLUSION. This study shows the first results of radiopaque UHMWPE sublaminar wires as part of a growth-guidance spinal system. UHMWPE sublaminar wires facilitated near-normal longitudinal spinal growth. All instrumentation remained stable throughout follow-up; no wire breakage or loosening occurred and no adverse local-tissue response to these wires was observed. Level of Evidence: N/A.
AB - STUDY DESIGN. In vivo analysis in an ovine model. OBJECTIVE. To evaluate the feasibility of radiopaque ultrahigh molecular weight polyethylene (UHMWPE) sublaminar wires in a growth-guidance spinal system by assessing stability, biocompatibility, and growth potential. SUMMARY OF BACKGROUND DATA. Several growth-guidance systems have been developed for the treatment of early-onset scoliosis. The use of gliding pedicle screws and metal sublaminar wires during these procedures can cause metal-on-metal debris formation and neurological deficits. Novel radiopaque UHMWPE wires are introduced to safely facilitate longitudinal growth and provide stability in a growth-guidance system for early-onset scoliosis. METHODS. Twelve immature sheep received posterior segmental spinal instrumentation; pedicle screws were inserted at L5 and radiopaque UHMWPE (bismuth trioxide) wires were passed sublaminarly at each level between L3 and T12 and fixed to dual cobalt-chromium rods. Four age-matched animals that were not operated were evaluated to serve as a control group. Radiographs were obtained to measure growth of the instrumented segment. After 24 weeks, the animals were killed and the spines were harvested for histological evaluation and high-resolution peripheral quantitative computed tomographic analysis. RESULTS. No neurological deficits occurred and all instrumentation remained stable. One animal died from an unknown cause. Substantial growth occurred in the instrumented segments (L5-T11) in the intervention group (27 ± 2 mm), which was not significantly different to the control group, (30 ± 4 mm, P = 0.42). High-resolution peripheral quantitative computed tomographic analysis clearly showed safe routing and fixation of the UHMWPE wires and instrumentation. Despite the noted growth, ectopic bone formation with the formation of bony bridges was observed in all animals. Histology revealed no evidence of chronic inflammation or wear debris. CONCLUSION. This study shows the first results of radiopaque UHMWPE sublaminar wires as part of a growth-guidance spinal system. UHMWPE sublaminar wires facilitated near-normal longitudinal spinal growth. All instrumentation remained stable throughout follow-up; no wire breakage or loosening occurred and no adverse local-tissue response to these wires was observed. Level of Evidence: N/A.
KW - early-onset scoliosis
KW - ectopic bone formation
KW - growth-guidance system
KW - large animal study
KW - radiopaque UHMWPE sublaminar wire
UR - http://www.scopus.com/inward/record.url?scp=84916892352&partnerID=8YFLogxK
U2 - 10.1097/BRS.0000000000000637
DO - 10.1097/BRS.0000000000000637
M3 - Article
C2 - 25417826
AN - SCOPUS:84916892352
SN - 0362-2436
VL - 39
SP - E1503-E1509
JO - Spine
JF - Spine
IS - 25
ER -