Novel method for noncontact measurement of particle temperatures

    Research output: Contribution to journalArticleAcademicpeer-review

    6 Citations (Scopus)
    1 Downloads (Pure)

    Abstract

    A nonintrusive temperature measurement technique is developed for noncontact measurement of the temperature of single particles with <200 µm dia. It is based on the temperature dependence of the fluorescence spectrum resulting from irradiation of a certain phosphor mixture with UV light by applying a mixture of two phosphors with fluorescence colors (blue and green) and a color shift from green to blue (with temperature increase from 20 to 280°C). An experimental setup is described for temperature measurement of particles based on the fluorescence color, together with the calibration of this system. The fluoroptic technique is applied to measure the temperature decrease of hot particles flowing down a cold chute. The measurements agree very well with thermocouple measurements. This novel technique can be applied to nonintrusive measurement of particle temperatures in (dense) multiparticle systems as encountered in packed and fluidized beds.
    Original languageEnglish
    Pages (from-to)773-782
    JournalAIChE Journal
    Volume41
    Issue number4
    DOIs
    Publication statusPublished - 1995

    Fingerprint

    Dive into the research topics of 'Novel method for noncontact measurement of particle temperatures'. Together they form a unique fingerprint.

    Cite this