Magnetically actuated glaucoma drainage device with adjustable flow properties after implantation

Inês C.F. Pereira (Corresponding author), Hans M. Wyss, Henny J.M. Beckers, Jaap M.J. den Toonder

Research output: Contribution to journalConference articlepeer-review

145 Downloads (Pure)

Abstract

Glaucoma is the second leading cause of preventable blindness worldwide, following cataract formation. A rise in the intraocular pressure (IOP) is a major risk factor for this disease, and results from an elevated resistance to aqueous humor outflow from the anterior chamber of the eye. Glaucoma drainage devices provide an alternative pathway through which the aqueous humor can effectively exit the eye, thereby lowering the IOP. However, post-operative IOP is unpredictable and current implants are deficient in maintaining IOP at optimal levels. To address this deficiency, we are developing an innovative, non-invasive magnetically actuated glaucoma implant with a hydrodynamic resistance that can be adjusted following surgery. This adjustment is achieved by integrating a magnetically actuated microvalve into the implant, which can open or close fluidic channels using an external magnetic stimulus. This microvalve was fabricated from poly(styrene–block–isobutylene–block–styrene), or ‘SIBS’, containing homogeneously dispersed magnetic microparticles. “Micro-pencil” valves of this material were fabricated using a combination of femtosecond laser machining with hot embossing. The glaucoma implant is comprised of a drainage tube and a housing element fabricated from two thermally bonded SIBS layers with the microvalve positioned in between. Microfluidic experiments involving actuating the magnetic micro-pencil with a moving external magnet confirmed the valving function. A pressure difference of around 6 mmHg was achieved, which is sufficient to overcome hypotony (i.e., too low IOP)—one of the most common post-operative complications following glaucoma surgery.
Original languageEnglish
Number of pages17
JournalEngineering Proceedings
Volume4
Issue number3
DOIs
Publication statusPublished - 16 Apr 2021
Event1st International Conference on Micromachines and Applications, ICMA 2021 - Virtual, Online
Duration: 15 Apr 202130 Apr 2021
Conference number: 1
https://micromachines2021.sciforum.net/

Keywords

  • Glaucoma, intraocular pressure (IOP), adjustable glaucoma implant, magnetic microvalve, microfabrication

Fingerprint

Dive into the research topics of 'Magnetically actuated glaucoma drainage device with adjustable flow properties after implantation'. Together they form a unique fingerprint.

Cite this