Abstract
In some visual experiments, light sources are required, whose luminance can be rapidly
and accurately varied over a wide range of intensities. In our group. a controller has
been developed that makes it possible to use normal fluorescent gas discharge tubes for
that purpose.
Original language | English |
---|---|
Pages (from-to) | 130-133 |
Number of pages | 4 |
Journal | IPO Annual Progress Report |
Volume | 25 |