This paper deals with the experimental and theoretical behavior of plybamboo (kind of plywood made out of bamboo) wall-panels subjected to lateral load. The wall-panels are part of a house design method proposed in the author's PhD thesis for prefabricated social housing in developing countries. Sixteen fullscaled wallpanels with or without window and door openings were tested and their theoretical capacities estimated. Design wind and seismic loads were determined according to the International Building Code 2000. The results showed that all the specimens present ductile behavior adequate for expected wind and seismic loads. The theoretical models for calculating lateral capacities of timber framed walls gave lower values than the experimental ones. The wall-panels sheathed with plybamboo and traditional plywood showed similar behavior and hence, plybamboo could be used as an alternative sheathing material in timber frame construction. Key Words: Shear-Walls, Plybamboo, Timber Framed Walls, Structural Panels, Bamboo Structures
LanguageEnglish
Pages123-144
Number of pages18
JournalHeron
Volume48
Issue number2
StatePublished - 2003

Fingerprint

Plywood
Bamboo
Timber
Structural panels
Shear walls
Developing countries

Cite this

Gonzalez Beltran, G. E., Herwijnen, van, F., Janssen, J. J. A., Moonen, S. P. G., & Gutierrez, J. A. (2003). Lateral resistance of plybamboo wall-panels. Heron, 48(2), 123-144.
Gonzalez Beltran, G.E. ; Herwijnen, van, F. ; Janssen, J.J.A. ; Moonen, S.P.G. ; Gutierrez, J.A./ Lateral resistance of plybamboo wall-panels. In: Heron. 2003 ; Vol. 48, No. 2. pp. 123-144
@article{6ecd6519838b48b9a98877f256eb4283,
title = "Lateral resistance of plybamboo wall-panels",
abstract = "This paper deals with the experimental and theoretical behavior of plybamboo (kind of plywood made out of bamboo) wall-panels subjected to lateral load. The wall-panels are part of a house design method proposed in the author's PhD thesis for prefabricated social housing in developing countries. Sixteen fullscaled wallpanels with or without window and door openings were tested and their theoretical capacities estimated. Design wind and seismic loads were determined according to the International Building Code 2000. The results showed that all the specimens present ductile behavior adequate for expected wind and seismic loads. The theoretical models for calculating lateral capacities of timber framed walls gave lower values than the experimental ones. The wall-panels sheathed with plybamboo and traditional plywood showed similar behavior and hence, plybamboo could be used as an alternative sheathing material in timber frame construction. Key Words: Shear-Walls, Plybamboo, Timber Framed Walls, Structural Panels, Bamboo Structures",
author = "{Gonzalez Beltran}, G.E. and {Herwijnen, van}, F. and J.J.A. Janssen and S.P.G. Moonen and J.A. Gutierrez",
year = "2003",
language = "English",
volume = "48",
pages = "123--144",
journal = "Heron",
issn = "0046-7316",
publisher = "Delft University of Technology",
number = "2",

}

Gonzalez Beltran, GE, Herwijnen, van, F, Janssen, JJA, Moonen, SPG & Gutierrez, JA 2003, 'Lateral resistance of plybamboo wall-panels' Heron, vol. 48, no. 2, pp. 123-144.

Lateral resistance of plybamboo wall-panels. / Gonzalez Beltran, G.E.; Herwijnen, van, F.; Janssen, J.J.A.; Moonen, S.P.G.; Gutierrez, J.A.

In: Heron, Vol. 48, No. 2, 2003, p. 123-144.

Research output: Contribution to journalArticleAcademicpeer-review

TY - JOUR

T1 - Lateral resistance of plybamboo wall-panels

AU - Gonzalez Beltran,G.E.

AU - Herwijnen, van,F.

AU - Janssen,J.J.A.

AU - Moonen,S.P.G.

AU - Gutierrez,J.A.

PY - 2003

Y1 - 2003

N2 - This paper deals with the experimental and theoretical behavior of plybamboo (kind of plywood made out of bamboo) wall-panels subjected to lateral load. The wall-panels are part of a house design method proposed in the author's PhD thesis for prefabricated social housing in developing countries. Sixteen fullscaled wallpanels with or without window and door openings were tested and their theoretical capacities estimated. Design wind and seismic loads were determined according to the International Building Code 2000. The results showed that all the specimens present ductile behavior adequate for expected wind and seismic loads. The theoretical models for calculating lateral capacities of timber framed walls gave lower values than the experimental ones. The wall-panels sheathed with plybamboo and traditional plywood showed similar behavior and hence, plybamboo could be used as an alternative sheathing material in timber frame construction. Key Words: Shear-Walls, Plybamboo, Timber Framed Walls, Structural Panels, Bamboo Structures

AB - This paper deals with the experimental and theoretical behavior of plybamboo (kind of plywood made out of bamboo) wall-panels subjected to lateral load. The wall-panels are part of a house design method proposed in the author's PhD thesis for prefabricated social housing in developing countries. Sixteen fullscaled wallpanels with or without window and door openings were tested and their theoretical capacities estimated. Design wind and seismic loads were determined according to the International Building Code 2000. The results showed that all the specimens present ductile behavior adequate for expected wind and seismic loads. The theoretical models for calculating lateral capacities of timber framed walls gave lower values than the experimental ones. The wall-panels sheathed with plybamboo and traditional plywood showed similar behavior and hence, plybamboo could be used as an alternative sheathing material in timber frame construction. Key Words: Shear-Walls, Plybamboo, Timber Framed Walls, Structural Panels, Bamboo Structures

M3 - Article

VL - 48

SP - 123

EP - 144

JO - Heron

T2 - Heron

JF - Heron

SN - 0046-7316

IS - 2

ER -

Gonzalez Beltran GE, Herwijnen, van F, Janssen JJA, Moonen SPG, Gutierrez JA. Lateral resistance of plybamboo wall-panels. Heron. 2003;48(2):123-144.