Abstract

Knowledge of the intrinsic material properties of healthy and diseased arterial tissue components is of great importance in diagnostics. This study describes an in vitro comparison of 13 porcine carotid arteries using inflation testing combined with functional ultrasound and bi-axial tensile testing. The measured tissue behavior was described using both a linear, but geometrically non-linear, one-parameter (neo-Hookean) model and a two-parameter non-linear (Demiray) model. The shear modulus estimated using the linear model resulted in good agreement between the ultrasound and tensile testing methods, GUS = 25 ± 5.7 kPa and GTT = 23 ± 5.4 kPa. No significant correspondence was observed for the non-linear model aUS = 1.0 ± 2.7 kPa vs. aTT = 17 ± 8.8 kPa, p ∼ 0); however, the exponential parameters were in correspondence (bUS = 12 ± 4.2 vs. bTT = 10 ± 1.7, p > 0.05). Estimation of more complex models in vivo is cumbersome considering the sensitivity of the model parameters to small changes in measurement data and the absence of intraluminal pressure data, endorsing the use of a simple, linear model in vivo.
Original languageEnglish
Pages (from-to)574-585
JournalUltrasound in Medicine and Biology
Volume42
Issue number2
DOIs
Publication statusPublished - 1 Feb 2016

Fingerprint

Nonlinear Dynamics
Economic Inflation
arteries
Carotid Arteries
Linear Models
Swine
Statistical Models
Pressure
shear
sensitivity
In Vitro Techniques

Cite this

@article{146801fa9f634d939701aad8c781de0c,
title = "Inflation and bi-axial tensile testing of healthy porcine carotid arteries",
abstract = "Knowledge of the intrinsic material properties of healthy and diseased arterial tissue components is of great importance in diagnostics. This study describes an in vitro comparison of 13 porcine carotid arteries using inflation testing combined with functional ultrasound and bi-axial tensile testing. The measured tissue behavior was described using both a linear, but geometrically non-linear, one-parameter (neo-Hookean) model and a two-parameter non-linear (Demiray) model. The shear modulus estimated using the linear model resulted in good agreement between the ultrasound and tensile testing methods, GUS = 25 ± 5.7 kPa and GTT = 23 ± 5.4 kPa. No significant correspondence was observed for the non-linear model aUS = 1.0 ± 2.7 kPa vs. aTT = 17 ± 8.8 kPa, p ∼ 0); however, the exponential parameters were in correspondence (bUS = 12 ± 4.2 vs. bTT = 10 ± 1.7, p > 0.05). Estimation of more complex models in vivo is cumbersome considering the sensitivity of the model parameters to small changes in measurement data and the absence of intraluminal pressure data, endorsing the use of a simple, linear model in vivo.",
author = "R.W. Boekhoven and M.F.J. Peters and M.C.M. Rutten and {van Sambeek}, {Marc R.H.M.} and {van de Vosse}, F.N. and R.G.P. Lopata",
year = "2016",
month = "2",
day = "1",
doi = "10.1016/j.ultrasmedbio.2015.09.019",
language = "English",
volume = "42",
pages = "574--585",
journal = "Ultrasound in Medicine and Biology",
issn = "0301-5629",
publisher = "Elsevier",
number = "2",

}

Inflation and bi-axial tensile testing of healthy porcine carotid arteries. / Boekhoven, R.W.; Peters, M.F.J.; Rutten, M.C.M.; van Sambeek, Marc R.H.M.; van de Vosse, F.N.; Lopata, R.G.P.

In: Ultrasound in Medicine and Biology, Vol. 42, No. 2, 01.02.2016, p. 574-585.

Research output: Contribution to journalArticleAcademicpeer-review

TY - JOUR

T1 - Inflation and bi-axial tensile testing of healthy porcine carotid arteries

AU - Boekhoven, R.W.

AU - Peters, M.F.J.

AU - Rutten, M.C.M.

AU - van Sambeek, Marc R.H.M.

AU - van de Vosse, F.N.

AU - Lopata, R.G.P.

PY - 2016/2/1

Y1 - 2016/2/1

N2 - Knowledge of the intrinsic material properties of healthy and diseased arterial tissue components is of great importance in diagnostics. This study describes an in vitro comparison of 13 porcine carotid arteries using inflation testing combined with functional ultrasound and bi-axial tensile testing. The measured tissue behavior was described using both a linear, but geometrically non-linear, one-parameter (neo-Hookean) model and a two-parameter non-linear (Demiray) model. The shear modulus estimated using the linear model resulted in good agreement between the ultrasound and tensile testing methods, GUS = 25 ± 5.7 kPa and GTT = 23 ± 5.4 kPa. No significant correspondence was observed for the non-linear model aUS = 1.0 ± 2.7 kPa vs. aTT = 17 ± 8.8 kPa, p ∼ 0); however, the exponential parameters were in correspondence (bUS = 12 ± 4.2 vs. bTT = 10 ± 1.7, p > 0.05). Estimation of more complex models in vivo is cumbersome considering the sensitivity of the model parameters to small changes in measurement data and the absence of intraluminal pressure data, endorsing the use of a simple, linear model in vivo.

AB - Knowledge of the intrinsic material properties of healthy and diseased arterial tissue components is of great importance in diagnostics. This study describes an in vitro comparison of 13 porcine carotid arteries using inflation testing combined with functional ultrasound and bi-axial tensile testing. The measured tissue behavior was described using both a linear, but geometrically non-linear, one-parameter (neo-Hookean) model and a two-parameter non-linear (Demiray) model. The shear modulus estimated using the linear model resulted in good agreement between the ultrasound and tensile testing methods, GUS = 25 ± 5.7 kPa and GTT = 23 ± 5.4 kPa. No significant correspondence was observed for the non-linear model aUS = 1.0 ± 2.7 kPa vs. aTT = 17 ± 8.8 kPa, p ∼ 0); however, the exponential parameters were in correspondence (bUS = 12 ± 4.2 vs. bTT = 10 ± 1.7, p > 0.05). Estimation of more complex models in vivo is cumbersome considering the sensitivity of the model parameters to small changes in measurement data and the absence of intraluminal pressure data, endorsing the use of a simple, linear model in vivo.

U2 - 10.1016/j.ultrasmedbio.2015.09.019

DO - 10.1016/j.ultrasmedbio.2015.09.019

M3 - Article

C2 - 26598396

VL - 42

SP - 574

EP - 585

JO - Ultrasound in Medicine and Biology

JF - Ultrasound in Medicine and Biology

SN - 0301-5629

IS - 2

ER -