Hybrid ceramic-supported thin PVA pervaporation membranes: long-term performance and thermal stability in the dehydration of alcohols

  • T.A. Peters
  • , N.E. Benes
  • , J.T.F. Keurentjes

    Research output: Contribution to journalArticleAcademicpeer-review

    Abstract

    The long-term performance and thermal stability of ceramic-supported cross-linked poly(vinyl)alcohol membranes has been examined over a period of six months up to a temperature of 100 ÝC. The membrane performance gradually changes at a temperature of 80 ÝC. After six months the water flux has increased from 1 to 1.4 kg m2 h-1, while the selectivity has decreased from 450 to 300. SEM analysis gives no indication that the decrease in performance is caused by defects in the membrane layers or a decreased adherence of the PVA layer to the ?-Al2O3 support. It is more likely that observed higher water flux and lower selectivity are caused by a decrease in cross-linking of the PVA-chains due to removal of maleic acid. At a temperature of 100 ÝC the decline in performance is accelerated. At this temperature the selectivity drops from 300 to 25, over a period of two weeks. At 100 ÝC, the thermal stability of the membranes is inadequate for most practical applications. © 2008 Elsevier B.V. All rights reserved
    Original languageEnglish
    Pages (from-to)7-11
    JournalJournal of Membrane Science
    Volume311
    Issue number1-2
    DOIs
    Publication statusPublished - 2008

    Fingerprint