High-Resolution Free-Breathing Quantitative First-Pass Perfusion Cardiac MR Using Dual-Echo Dixon With Spatio-Temporal Acceleration

  • Joao Tourais
  • , Cian M. Scannell
  • , Torben Schneider
  • , Ebraham Alskaf
  • , Richard Crawley
  • , Filippo Bosio
  • , Javier Sanchez-Gonzalez
  • , Mariya Doneva
  • , Christophe Schülke
  • , Jakob Meineke
  • , Jochen Keupp
  • , Jouke Smink
  • , Marcel Breeuwer
  • , Amedeo Chiribiri
  • , Markus Henningsson
  • , Teresa Correia (Corresponding author)

Research output: Contribution to journalArticleAcademicpeer-review

69 Downloads (Pure)

Abstract

Introduction: To develop and test the feasibility of free-breathing (FB), high-resolution quantitative first-pass perfusion cardiac MR (FPP-CMR) using dual-echo Dixon (FOSTERS; Fat-water separation for mOtion-corrected Spatio-TEmporally accelerated myocardial peRfuSion).

Materials and Methods: FOSTERS was performed in FB using a dual-saturation single-bolus acquisition with dual-echo Dixon and a dynamically variable Cartesian k-t undersampling (8-fold) approach, with low-rank and sparsity constrained reconstruction, to achieve high-resolution FPP-CMR images. FOSTERS also included automatic in-plane motion estimation and T 2 * correction to obtain quantitative myocardial blood flow (MBF) maps. High-resolution (1.6 x 1.6 mm 2) FB FOSTERS was evaluated in eleven patients, during rest, against standard-resolution (2.6 x 2.6 mm 2) 2-fold SENSE-accelerated breath-hold (BH) FPP-CMR. In addition, MBF was computed for FOSTERS and spatial wavelet-based compressed sensing (CS) reconstruction. Two cardiologists scored the image quality (IQ) of FOSTERS, CS, and standard BH FPP-CMR images using a 4-point scale (1-4, non-diagnostic - fully diagnostic).

Results: FOSTERS produced high-quality images without dark-rim and with reduced motion-related artifacts, using an 8x accelerated FB acquisition. FOSTERS and standard BH FPP-CMR exhibited excellent IQ with an average score of 3.5 ± 0.6 and 3.4 ± 0.6 (no statistical difference, p > 0.05), respectively. CS images exhibited severe artifacts and high levels of noise, resulting in an average IQ score of 2.9 ± 0.5. MBF values obtained with FOSTERS presented a lower variance than those obtained with CS.

Discussion: FOSTERS enabled high-resolution FB FPP-CMR with MBF quantification. Combining motion correction with a low-rank and sparsity-constrained reconstruction results in excellent image quality.

Original languageEnglish
Article number884221
Number of pages10
JournalFrontiers in Cardiovascular Medicine
Volume9
DOIs
Publication statusPublished - 29 Apr 2022

Keywords

  • Dixon
  • free-breathing
  • high-resolution
  • motion correction
  • myocardial perfusion
  • quantitative myocardial blood flow

Fingerprint

Dive into the research topics of 'High-Resolution Free-Breathing Quantitative First-Pass Perfusion Cardiac MR Using Dual-Echo Dixon With Spatio-Temporal Acceleration'. Together they form a unique fingerprint.

Cite this