Abstract
Coherent wideband frequency-domain measurements of the complex frequency response of millimeter wave indoor radio channels are discussed. In addition, results of measurements performed in a 2 GHz band centered around 58 GHz will be presented. It is shown that a 40 dB dynamic range and a 400 ns aliasing-free range are sufficient for a correct estimation of the rms delay spread from the measurement data
Original language | English |
---|---|
Pages (from-to) | 1017-1022 |
Number of pages | 6 |
Journal | IEEE Transactions on Instrumentation and Measurement |
Volume | 44 |
DOIs | |