Abstract
In this paper, a semi-analytical model is derived to calculate the magnetic flux density around a magnetic shield with finite dimensions. The proposed modeling is based on Fourier modeling, which is extended with mode-matching. The described model has less than 0.2(%) error with respect to finite element modeling for the given configuration. Furthermore, the paper shows that assuming a magnetic shield with infinite dimensions introduces a significant error with respect to a magnetic shield with finite dimensions
| Original language | English |
|---|---|
| Pages (from-to) | 1593-1596 |
| Number of pages | 4 |
| Journal | IEEE Transactions on Magnetics |
| Volume | 49 |
| Issue number | 5 |
| DOIs | |
| Publication status | Published - 2013 |
Fingerprint
Dive into the research topics of 'Field calculations for magnetic shielding : fourier modeling extended with mode-matching technique applied on a shield with finite dimensions'. Together they form a unique fingerprint.Cite this