Abstract
The feasibility to measure fast alpha particles using Active Charge Exchange Recombination Spectroscopy (CXRS) on ITER is investigated. Through modelling of the charge exchange spectral line for fast ions together with the expected background emission, the signal-to-noise ratio has been calculated as a function of the diagnostic design parameters. Combining the CXRS data from both the heating and the diagnostic neutral beams on ITER, information on the fast ion energy spectrum up to 1 MeV can be obtained for the parameters of the ITER core CXRS diagnostic design, provided that the signal is binned in 100 keV bins and a time resolution of Isec is used.
Original language | English |
---|---|
Title of host publication | 38th EPS Conference on Plasma Physics 2011, EPS 2011 - Europhysics Conference Abstracts |
Pages | 769-772 |
Number of pages | 4 |
Volume | 35 1 |
Publication status | Published - 1 Dec 2011 |
Event | 38th European Physical Society Conference on Plasma Physics (EPS 2011) - Strasbourg, France Duration: 27 Jun 2011 → 1 Jul 2011 Conference number: 38 |
Conference
Conference | 38th European Physical Society Conference on Plasma Physics (EPS 2011) |
---|---|
Abbreviated title | EPS 2011 |
Country/Territory | France |
City | Strasbourg |
Period | 27/06/11 → 1/07/11 |