Fault-Tolerant Control of Series Connectable Modular Full-Bridge Inverter Mitigating Open Switch Faults

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

1 Downloads (Pure)

Abstract

This paper proposes the fault-tolerant control of a series connectable modular full-bridge inverter in case of an open switch fault. The faulty main switch is detected and identified by comparing the value of the measured phase node output voltage with the PWM signal generated for the respective phase leg. The series switch fault is detected and identified by comparing the measured output voltage of the phase legs connected by the series switch with a reference value. The post-fault control following an open main/series switch fault is realized by modifying several reference values in the healthy control system and is validated for several fault scenarios.

Original languageEnglish
Title of host publication2020 22nd European Conference on Power Electronics and Applications, EPE 2020 ECCE Europe
PublisherInstitute of Electrical and Electronics Engineers
Number of pages9
ISBN (Electronic)9789075815368
DOIs
Publication statusPublished - Sep 2020
Event22nd European Conference on Power Electronics and Applications, EPE 2020 ECCE Europe - Lyon, France
Duration: 7 Sep 202011 Sep 2020

Conference

Conference22nd European Conference on Power Electronics and Applications, EPE 2020 ECCE Europe
CountryFrance
CityLyon
Period7/09/2011/09/20

Keywords

  • control of drive
  • fault handling strategy
  • fault tolerance
  • faults
  • multiphase drive

Fingerprint Dive into the research topics of 'Fault-Tolerant Control of Series Connectable Modular Full-Bridge Inverter Mitigating Open Switch Faults'. Together they form a unique fingerprint.