Purpose: To compare global functional parameters determined from a stack of cinematographic MR images of mouse heart by a manual segmentation and an automatic segmentation algorithm. Materials and Methods: The manual and automatic segmentation results of 22 mouse hearts were compared. The automatic segmentation was based on propagation of a minimum cost algorithm in polar space starting from manually drawn contours in one heart phase. Intra- and interobserver variability as well as validity of the automatic segmentation was determined. To test the reproducibility of the algorithm the variability was calculated from the intra-and interobserver input. Results: The mean time of segmentation for one dataset was around 10 minutes and ≈2.5 hours for automatic and manual segmentation, respectively. There were no significant differences between the automatic and the manual segmentation except for the end systolic epicardial volume. The automatically derived volumes correlated well with the manually derived volumes (R2 = 0.90); left ventricular mass with and without papillary muscle showed a correlation R2 of 0.74 and 0.76, respectively. The manual intraobserver variability was superior to the interobserver variability and the variability of the automatic segmentation, while the manual interobserver variability was comparable to the variability of the automatic segmentation. The automatic segmentation algorithm reduced the bias of the intra- and interobserver variability. Conclusion: We conclude that automatic segmentation of the mouse heart provides a fast and valid alternative to manual segmentation of the mouse heart.

Original languageEnglish
Pages (from-to)86-93
Number of pages8
JournalJournal of Magnetic Resonance Imaging
Volume27
Issue number1
DOIs
Publication statusPublished - Jan 2008

Keywords

  • Automatic
  • CINE MRI
  • Global functional parameter
  • Mouse heart
  • Quantitative analysis
  • Segmentation

Fingerprint

Dive into the research topics of 'Evaluation of manual and automatic segmentation of the mouse heart from CINE MR images'. Together they form a unique fingerprint.

Cite this