Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images

W. Pistoia, B. Rietbergen, van, E.M. Lochmüller, C.A. Lill, F. Eckstein, P. Rüegsegger

Research output: Contribution to journalArticleAcademicpeer-review

366 Citations (Scopus)
3 Downloads (Pure)

Abstract

There is increasing evidence that, in addition to bone mass, bone microarchitecture and its mechanical load distribution are important factors for the determination of bone strength. Recently, it has been shown that new high-resolution imaging techniques in combination with new modeling algorithms based on the finite element (FE) method can account for these additional factors. Such models thus could provide more relevant information for the estimation of bone failure load. The purpose of the present study was to determine whether results of whole-bone micro-FE (microFE) analyses with models based on three-dimensional peripheral quantitative computer tomography (3D-pQCT) images (isotropic voxel resolution of 165 microm) could predict the failure load of the hum! an radius more accurately than results with dual-energy X-ray absorptiometry (DXA) or bone morphology measurements. For this purpose, microFE models were created using 54 embalmed cadaver arms. It was assumed that bone failure would be initiated if a certain percentage of the bone tissue (varied from 1% to 7%) would be strained beyond the tissue yield strain. The external force that produced this tissue strain was calculated from the FE analyses. These predictions were correlated with results of real compression testing on the same cadaver arms. The results of these compression tests were also correlated with results of DXA and structural measurements of these arms. The compression tests produced Colles-type fractures in the distal 4 cm of the radius. The predicted failure loads calculated from the FE analysis agreed well with those measured in the experiments (R(2) = 0.75 p <0.001). Lower correlations were found with bone mass (R(2) = 0.48, p <0.001) and bone structural p! arameters (R(2) = 0.57 p <0.001). We conclude that application of the techniques investigated here can lead to a better prediction of the bone failure load for bone in vivo than is possible from DXA measurements, structural parameters, or a combination thereof.
Original languageEnglish
Pages (from-to)842-848
JournalBone
Volume30
Issue number6
DOIs
Publication statusPublished - 2002

Fingerprint

Finite Element Analysis
Tomography
Bone and Bones
Photon Absorptiometry
Cadaver
Computer Peripherals
Colles' Fracture

Cite this

@article{bbf44b00e5b2416a8dc3010271d88dca,
title = "Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images",
abstract = "There is increasing evidence that, in addition to bone mass, bone microarchitecture and its mechanical load distribution are important factors for the determination of bone strength. Recently, it has been shown that new high-resolution imaging techniques in combination with new modeling algorithms based on the finite element (FE) method can account for these additional factors. Such models thus could provide more relevant information for the estimation of bone failure load. The purpose of the present study was to determine whether results of whole-bone micro-FE (microFE) analyses with models based on three-dimensional peripheral quantitative computer tomography (3D-pQCT) images (isotropic voxel resolution of 165 microm) could predict the failure load of the hum! an radius more accurately than results with dual-energy X-ray absorptiometry (DXA) or bone morphology measurements. For this purpose, microFE models were created using 54 embalmed cadaver arms. It was assumed that bone failure would be initiated if a certain percentage of the bone tissue (varied from 1{\%} to 7{\%}) would be strained beyond the tissue yield strain. The external force that produced this tissue strain was calculated from the FE analyses. These predictions were correlated with results of real compression testing on the same cadaver arms. The results of these compression tests were also correlated with results of DXA and structural measurements of these arms. The compression tests produced Colles-type fractures in the distal 4 cm of the radius. The predicted failure loads calculated from the FE analysis agreed well with those measured in the experiments (R(2) = 0.75 p <0.001). Lower correlations were found with bone mass (R(2) = 0.48, p <0.001) and bone structural p! arameters (R(2) = 0.57 p <0.001). We conclude that application of the techniques investigated here can lead to a better prediction of the bone failure load for bone in vivo than is possible from DXA measurements, structural parameters, or a combination thereof.",
author = "W. Pistoia and {Rietbergen, van}, B. and E.M. Lochm{\"u}ller and C.A. Lill and F. Eckstein and P. R{\"u}egsegger",
year = "2002",
doi = "10.1016/S8756-3282(02)00736-6",
language = "English",
volume = "30",
pages = "842--848",
journal = "Bone",
issn = "8756-3282",
publisher = "Elsevier",
number = "6",

}

Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images. / Pistoia, W.; Rietbergen, van, B.; Lochmüller, E.M.; Lill, C.A.; Eckstein, F.; Rüegsegger, P.

In: Bone, Vol. 30, No. 6, 2002, p. 842-848.

Research output: Contribution to journalArticleAcademicpeer-review

TY - JOUR

T1 - Estimation of distal radius failure load with micro-finite element analysis models based on three-dimensional peripheral quantitative computed tomography images

AU - Pistoia, W.

AU - Rietbergen, van, B.

AU - Lochmüller, E.M.

AU - Lill, C.A.

AU - Eckstein, F.

AU - Rüegsegger, P.

PY - 2002

Y1 - 2002

N2 - There is increasing evidence that, in addition to bone mass, bone microarchitecture and its mechanical load distribution are important factors for the determination of bone strength. Recently, it has been shown that new high-resolution imaging techniques in combination with new modeling algorithms based on the finite element (FE) method can account for these additional factors. Such models thus could provide more relevant information for the estimation of bone failure load. The purpose of the present study was to determine whether results of whole-bone micro-FE (microFE) analyses with models based on three-dimensional peripheral quantitative computer tomography (3D-pQCT) images (isotropic voxel resolution of 165 microm) could predict the failure load of the hum! an radius more accurately than results with dual-energy X-ray absorptiometry (DXA) or bone morphology measurements. For this purpose, microFE models were created using 54 embalmed cadaver arms. It was assumed that bone failure would be initiated if a certain percentage of the bone tissue (varied from 1% to 7%) would be strained beyond the tissue yield strain. The external force that produced this tissue strain was calculated from the FE analyses. These predictions were correlated with results of real compression testing on the same cadaver arms. The results of these compression tests were also correlated with results of DXA and structural measurements of these arms. The compression tests produced Colles-type fractures in the distal 4 cm of the radius. The predicted failure loads calculated from the FE analysis agreed well with those measured in the experiments (R(2) = 0.75 p <0.001). Lower correlations were found with bone mass (R(2) = 0.48, p <0.001) and bone structural p! arameters (R(2) = 0.57 p <0.001). We conclude that application of the techniques investigated here can lead to a better prediction of the bone failure load for bone in vivo than is possible from DXA measurements, structural parameters, or a combination thereof.

AB - There is increasing evidence that, in addition to bone mass, bone microarchitecture and its mechanical load distribution are important factors for the determination of bone strength. Recently, it has been shown that new high-resolution imaging techniques in combination with new modeling algorithms based on the finite element (FE) method can account for these additional factors. Such models thus could provide more relevant information for the estimation of bone failure load. The purpose of the present study was to determine whether results of whole-bone micro-FE (microFE) analyses with models based on three-dimensional peripheral quantitative computer tomography (3D-pQCT) images (isotropic voxel resolution of 165 microm) could predict the failure load of the hum! an radius more accurately than results with dual-energy X-ray absorptiometry (DXA) or bone morphology measurements. For this purpose, microFE models were created using 54 embalmed cadaver arms. It was assumed that bone failure would be initiated if a certain percentage of the bone tissue (varied from 1% to 7%) would be strained beyond the tissue yield strain. The external force that produced this tissue strain was calculated from the FE analyses. These predictions were correlated with results of real compression testing on the same cadaver arms. The results of these compression tests were also correlated with results of DXA and structural measurements of these arms. The compression tests produced Colles-type fractures in the distal 4 cm of the radius. The predicted failure loads calculated from the FE analysis agreed well with those measured in the experiments (R(2) = 0.75 p <0.001). Lower correlations were found with bone mass (R(2) = 0.48, p <0.001) and bone structural p! arameters (R(2) = 0.57 p <0.001). We conclude that application of the techniques investigated here can lead to a better prediction of the bone failure load for bone in vivo than is possible from DXA measurements, structural parameters, or a combination thereof.

U2 - 10.1016/S8756-3282(02)00736-6

DO - 10.1016/S8756-3282(02)00736-6

M3 - Article

VL - 30

SP - 842

EP - 848

JO - Bone

JF - Bone

SN - 8756-3282

IS - 6

ER -