Environmental applications of large volume injection in capillary GC using PTV injectors

J.G.J. Mol, Mariken Althuizen, J.G.M. Janssen, C.A.M.G. Cramers, U.A.T. Brinkman

Research output: Contribution to journalArticleAcademicpeer-review

61 Citations (Scopus)
1 Downloads (Pure)

Abstract

Temp. programmable (PTV) injectors with packed wide-bore (.apprx.3.5 mm inside diam.) liners are used for large vol. injection in capillary gas chromatog. to simplify and/or improve off-line sample pretreatment procedures. A simple procedure to optimize large vol. PTV injection is described. System performance, i.e., linearity and repeatability, was evaluated for polar N/P contg. pesticides (PTV-GC-NPD) and organochlorine pesticides (PTV-GC-ECD) in river water exts. and for polycyclic arom. hydrocarbons (PAH) in river sediment (PTV-GC-MS). [on SciFinder (R)]
Original languageEnglish
Pages (from-to)69-79
Number of pages11
JournalJournal of High Resolution Chromatography
Volume19
Issue number2
DOIs
Publication statusPublished - 1996

Fingerprint

Pesticides
Rivers
Polycyclic aromatic hydrocarbons
Hydrocarbons
Sediments
Gases
Water
neodymium pyrocatechin disulfonate

Cite this

Mol, J. G. J., Althuizen, M., Janssen, J. G. M., Cramers, C. A. M. G., & Brinkman, U. A. T. (1996). Environmental applications of large volume injection in capillary GC using PTV injectors. Journal of High Resolution Chromatography, 19(2), 69-79. https://doi.org/10.1002/jhrc.1240190203
Mol, J.G.J. ; Althuizen, Mariken ; Janssen, J.G.M. ; Cramers, C.A.M.G. ; Brinkman, U.A.T. / Environmental applications of large volume injection in capillary GC using PTV injectors. In: Journal of High Resolution Chromatography. 1996 ; Vol. 19, No. 2. pp. 69-79.
@article{3d999e09bc3b42a6ae2b51e15062088d,
title = "Environmental applications of large volume injection in capillary GC using PTV injectors",
abstract = "Temp. programmable (PTV) injectors with packed wide-bore (.apprx.3.5 mm inside diam.) liners are used for large vol. injection in capillary gas chromatog. to simplify and/or improve off-line sample pretreatment procedures. A simple procedure to optimize large vol. PTV injection is described. System performance, i.e., linearity and repeatability, was evaluated for polar N/P contg. pesticides (PTV-GC-NPD) and organochlorine pesticides (PTV-GC-ECD) in river water exts. and for polycyclic arom. hydrocarbons (PAH) in river sediment (PTV-GC-MS). [on SciFinder (R)]",
author = "J.G.J. Mol and Mariken Althuizen and J.G.M. Janssen and C.A.M.G. Cramers and U.A.T. Brinkman",
year = "1996",
doi = "10.1002/jhrc.1240190203",
language = "English",
volume = "19",
pages = "69--79",
journal = "Journal of High Resolution Chromatography",
issn = "0935-6304",
publisher = "Wiley",
number = "2",

}

Environmental applications of large volume injection in capillary GC using PTV injectors. / Mol, J.G.J.; Althuizen, Mariken; Janssen, J.G.M.; Cramers, C.A.M.G.; Brinkman, U.A.T.

In: Journal of High Resolution Chromatography, Vol. 19, No. 2, 1996, p. 69-79.

Research output: Contribution to journalArticleAcademicpeer-review

TY - JOUR

T1 - Environmental applications of large volume injection in capillary GC using PTV injectors

AU - Mol, J.G.J.

AU - Althuizen, Mariken

AU - Janssen, J.G.M.

AU - Cramers, C.A.M.G.

AU - Brinkman, U.A.T.

PY - 1996

Y1 - 1996

N2 - Temp. programmable (PTV) injectors with packed wide-bore (.apprx.3.5 mm inside diam.) liners are used for large vol. injection in capillary gas chromatog. to simplify and/or improve off-line sample pretreatment procedures. A simple procedure to optimize large vol. PTV injection is described. System performance, i.e., linearity and repeatability, was evaluated for polar N/P contg. pesticides (PTV-GC-NPD) and organochlorine pesticides (PTV-GC-ECD) in river water exts. and for polycyclic arom. hydrocarbons (PAH) in river sediment (PTV-GC-MS). [on SciFinder (R)]

AB - Temp. programmable (PTV) injectors with packed wide-bore (.apprx.3.5 mm inside diam.) liners are used for large vol. injection in capillary gas chromatog. to simplify and/or improve off-line sample pretreatment procedures. A simple procedure to optimize large vol. PTV injection is described. System performance, i.e., linearity and repeatability, was evaluated for polar N/P contg. pesticides (PTV-GC-NPD) and organochlorine pesticides (PTV-GC-ECD) in river water exts. and for polycyclic arom. hydrocarbons (PAH) in river sediment (PTV-GC-MS). [on SciFinder (R)]

U2 - 10.1002/jhrc.1240190203

DO - 10.1002/jhrc.1240190203

M3 - Article

VL - 19

SP - 69

EP - 79

JO - Journal of High Resolution Chromatography

JF - Journal of High Resolution Chromatography

SN - 0935-6304

IS - 2

ER -