Abstract
Current diagnostics of a high voltage corona discharge setup are analyzed, because the presence of high amplitude oscillations prohibited to obtain a realistic current signal. By means of an electromagnetic computation in FEKO, the observed oscillations have been identified. Current distributions indicated setup improvement by adding a 50Ω damping resistor in the circuit. A realistic current signal is now obtained.
| Original language | English |
|---|---|
| Title of host publication | EMC EUROPE 2012 - International Symposium on Electromagnetic Compatibility, Proceedings |
| Place of Publication | Piscataway |
| Publisher | Institute of Electrical and Electronics Engineers |
| Number of pages | 4 |
| ISBN (Print) | 9781467307185 |
| DOIs | |
| Publication status | Published - 1 Dec 2012 |
| Event | 11th International Symposium on Electromagnetic Compatibility, EMC EUROPE 2012 - Rome, Italy Duration: 17 Sept 2012 → 21 Sept 2012 Conference number: 11 |
Conference
| Conference | 11th International Symposium on Electromagnetic Compatibility, EMC EUROPE 2012 |
|---|---|
| Abbreviated title | EMC Europe 2012 |
| Country/Territory | Italy |
| City | Rome |
| Period | 17/09/12 → 21/09/12 |