Electrical diagnostics in a HV corona streamer discharge setup: Improved current measurement through electromagnetic frequency response analysis

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

Abstract

Current diagnostics of a high voltage corona discharge setup are analyzed, because the presence of high amplitude oscillations prohibited to obtain a realistic current signal. By means of an electromagnetic computation in FEKO, the observed oscillations have been identified. Current distributions indicated setup improvement by adding a 50Ω damping resistor in the circuit. A realistic current signal is now obtained.

Original languageEnglish
Title of host publicationEMC EUROPE 2012 - International Symposium on Electromagnetic Compatibility, Proceedings
Place of PublicationPiscataway
PublisherInstitute of Electrical and Electronics Engineers
Number of pages4
ISBN (Print)9781467307185
DOIs
Publication statusPublished - 1 Dec 2012
Event11th International Symposium on Electromagnetic Compatibility, EMC EUROPE 2012 - Rome, Italy
Duration: 17 Sept 201221 Sept 2012
Conference number: 11

Conference

Conference11th International Symposium on Electromagnetic Compatibility, EMC EUROPE 2012
Abbreviated titleEMC Europe 2012
Country/TerritoryItaly
CityRome
Period17/09/1221/09/12

Fingerprint

Dive into the research topics of 'Electrical diagnostics in a HV corona streamer discharge setup: Improved current measurement through electromagnetic frequency response analysis'. Together they form a unique fingerprint.

Cite this