Correlation of Carotid Doppler Blood Flow With Invasive Cardiac Output Measurements in Cardiac Surgery Patients

Joris van Houte (Corresponding author), Frederik J. Mooi, Leon J. Montenij, Loek P.B. Meijs, Irene Suriani, Bente C.M. Conjaerts, Saskia Houterman, R. Arthur Bouwman

Research output: Contribution to journalArticleAcademicpeer-review

12 Citations (Scopus)
176 Downloads (Pure)

Abstract

Objective: Carotid Doppler ultrasound has been a topic of recent interest, as it may be a promising noninvasive hemodynamic monitoring tool. In this study, the relation between carotid artery blood flow and invasive cardiac output (CO) was evaluated. Design: A prospective, observational study. Setting: A single-institution, tertiary referral hospital. Participants: Eighteen elective cardiac surgery patients. Interventions: CO was measured by calibrated pulse contour analysis. Simultaneously, carotid artery pulsed-wave Doppler measurements were obtained in the operating room in three clinical settings: after induction of anesthesia (T1), after a passive leg raise maneuverer (T2), and at the end of surgery (T3). Measurements and Main Results: Correlation and trending between carotid artery blood flow and invasive CO were evaluated. Furthermore, two Bland-Altman plots were constructed to evaluate the level of agreement between carotid artery-derived CO and invasive CO measurements. Carotid artery blood flow correlated moderately with invasive CO (ρ = 0.67, 95% confidence interval 0.56-0.76, p < 0.05). Concordance between the percentage change of carotid artery blood flow and invasive CO from T1 to T3 was 72%. The level of agreement between carotid artery-derived CO and invasive CO was ±2.29; ±2.57 L/min, with a bias of 0.1; –0.54 L/min, and mean error of 50% and 48%, for the two Bland-Altman analyses, respectively. Intraexamination precision was acceptable. Conclusions: In cardiac surgery patients, carotid artery blood flow correlated moderately with invasive CO measurements. However, the trending ability of carotid artery blood flow was poor, and carotid artery-derived CO tended not to be interchangeable with invasive CO.

Original languageEnglish
Pages (from-to)1081-1091
Number of pages11
JournalJournal of Cardiothoracic and Vascular Anesthesia
Volume36
Issue number4
DOIs
Publication statusPublished - Apr 2022

Bibliographical note

Funding Information:
The authors are grateful to Jules Olsthoorn, MD, department of cardiothoracic surgery, for his assistance in editing the figures to the professional standards of this journal.

Funding

The authors are grateful to Jules Olsthoorn, MD, department of cardiothoracic surgery, for his assistance in editing the figures to the professional standards of this journal.

Keywords

  • cardiac output
  • cardiac surgery
  • carotid artery blood flow
  • carotid Doppler ultrasound
  • cerebral blood flow
  • velocity time integral
  • Reproducibility of Results
  • Prospective Studies
  • Humans
  • Cardiac Surgical Procedures
  • Thermodilution
  • Cardiac Output/physiology
  • Monitoring, Intraoperative

Fingerprint

Dive into the research topics of 'Correlation of Carotid Doppler Blood Flow With Invasive Cardiac Output Measurements in Cardiac Surgery Patients'. Together they form a unique fingerprint.