TY - JOUR
T1 - Compressive mechanical properties of atherosclerotic plaques-Indentation test to characterise the local anisotropic behaviour
AU - Chai, C.K.
AU - Speelman, L.
AU - Oomens, C.W.J.
AU - Baaijens, F.P.T.
PY - 2014
Y1 - 2014
N2 - Accurate material models and associated parameters of atherosclerotic plaques are crucial for reliable biomechanical plaque prediction models. These biomechanical models have the potential to increase our understanding of plaque progression and failure, possibly improving risk assessment of plaque rupture, which is the main cause of ischaemic strokes and myocardial infarction. However, experimental biomechanical data on atherosclerotic plaque tissue is scarce and shows a high variability. In addition, most of the biomechanical models assume isotropic behaviour of plaque tissue, which is a general over-simplification. This review discusses the past and the current literature that focus on mechanical properties of plaque derived from compression experiments, using unconfined compression, micro-indentation or nano-indentation. Results will be discussed and the techniques will be mutually compared. Thereafter, an in-house developed indentation method combined with an inverse finite element method is introduced, allowing analysis of the local anisotropic mechanical properties of atherosclerotic plaques. The advantages and limitations of this method will be evaluated and compared to other methods reported in literature.
AB - Accurate material models and associated parameters of atherosclerotic plaques are crucial for reliable biomechanical plaque prediction models. These biomechanical models have the potential to increase our understanding of plaque progression and failure, possibly improving risk assessment of plaque rupture, which is the main cause of ischaemic strokes and myocardial infarction. However, experimental biomechanical data on atherosclerotic plaque tissue is scarce and shows a high variability. In addition, most of the biomechanical models assume isotropic behaviour of plaque tissue, which is a general over-simplification. This review discusses the past and the current literature that focus on mechanical properties of plaque derived from compression experiments, using unconfined compression, micro-indentation or nano-indentation. Results will be discussed and the techniques will be mutually compared. Thereafter, an in-house developed indentation method combined with an inverse finite element method is introduced, allowing analysis of the local anisotropic mechanical properties of atherosclerotic plaques. The advantages and limitations of this method will be evaluated and compared to other methods reported in literature.
U2 - 10.1016/j.jbiomech.2014.01.018
DO - 10.1016/j.jbiomech.2014.01.018
M3 - Article
C2 - 24480703
SN - 0021-9290
VL - 47
SP - 784
EP - 792
JO - Journal of Biomechanics
JF - Journal of Biomechanics
IS - 4
ER -