Abstract
In this paper, we explore the use of channel state information (CSI) from a WiFi system to estimate the breathing rate of a person in a room. In order to extract WiFi CSI components that are sensitive to breathing, we propose to consider the delay domain channel impulse response (CIR), while most state-of-the-art methods consider its frequency domain representation. One obstacle while processing the CSI data is that its amplitude and phase are highly distorted by measurement uncertainties. We thus also propose an amplitude calibration method and a phase offset calibration method for CSI measured in orthogonal frequency-division multiplexing (OFDM) multiple- input multiple-output (MIMO) systems. Finally, we implement a complete breathing rate estimation system in order to showcase the effectiveness of our proposed calibration and CSI extraction methods.
| Original language | English |
|---|---|
| Title of host publication | 2021 IEEE Workshop on Signal Processing Systems (SiPS) |
| Publisher | Institute of Electrical and Electronics Engineers |
| Pages | 217-222 |
| Number of pages | 6 |
| ISBN (Electronic) | 978-1-6654-0144-9 |
| DOIs | |
| Publication status | Published - 13 Nov 2021 |
| Event | 35th IEEE Workshop on Signal Processing Systems, SiPS 2021 - Coimbra, Portugal Duration: 19 Oct 2021 → 21 Oct 2021 Conference number: 35 |
Conference
| Conference | 35th IEEE Workshop on Signal Processing Systems, SiPS 2021 |
|---|---|
| Abbreviated title | SiPS 2021 |
| Country/Territory | Portugal |
| City | Coimbra |
| Period | 19/10/21 → 21/10/21 |
Bibliographical note
Funding Information:VI. CONCLUSIONS In this paper, we show that robust breathing rate estimation from CSI relies on careful selection of the best CSI component, especially in the delay domain. To this end, we introduce a dominant path-based CSI amplitude calibration method and a linear component-based CSI phase calibration method for preprocessing of the CSI data. The calibration methods combined with the delay domain filtering leads to a better CSI extraction compared to PhaseBeat and its variants.Furthermore, we show that the breathing rate can be estimated directly from calibrated complex-valued CSI or CIR. Compared to observing only the phase values, the estimation from complex-valued CSI achieves the highest accuracy. ACKNOWLEDGMENT This research has been kindly supported by the Swiss National Science Foundation under Grant-ID 182621. REFERENCES [1] S. Rolfe, “The importance of respiratory rate monitor-ing,” British Journal of Nursing, vol. 28, no. 8, pp. 504– 508, Apr. 2019. [2] S. R. Pandi-Perumal, D. W. Spence, and A. S. Ba-Hammam, “Polysomnography: An overview,” in Primary Care Sleep Medicine, J. F. Pagel and S. R. Pandi-Perumal, Eds. Springer New York, 2014, pp. 29–42. [3] S.Costanzo,“Software-definedDopplerradarsensorfor human breathing detection”, Sensors, vol. 19, no. 14, p. 3085, Jul. 2019. [4] A. Droitcour, O. Boric-Lubecke, and G. Kovacs, “Signal-to-Noise Ratio in Doppler radar system for heart and respiratory rate measurements”, IEEE Transactions on Microwave Theory and Techniques, vol. 57, no. 10, pp. 2498–2507, Oct. 2009. [5] L. Anitori, A. de Jong, and F. Nennie, “FMCW radar for life-sign detection”, in 2009 IEEE Radar Conference. IEEE, 2009, pp. 1–6. [6] Z. Peng, J. M. Munoz-Ferreras, Y. Tang, C. Liu, R. Gomez-Garcia, L. Ran, and C. Li, “A portable FMCW interferometry radar with programmable Low-IF archi-tecture for localization, ISAR imaging, and vital sign tracking,” IEEE Transactions on Microwave Theory and Techniques, vol. 65, no. 4, pp. 1334–1344, Apr. 2017. [7] J. Liu, Y. Wang, Y. Chen, J. Yang, X. Chen, and J. Cheng, “Tracking vital signs during sleep leveraging off-the-shelf wifi,” in Proceedingsof the 16th ACM International Symposium on Mobile Ad Hoc Networking and Com-puting, ser. MobiHoc ’15. Association for Computing Machinery, 2015, p. 267276. [8] Y. Ma, G. Zhou, and S. Wang, “WiFi sensing with channel state information: A survey,” ACM Computing Surveys, vol. 52, no. 3, pp. 1–36, Jul. 2019. [9] S. Lee, Y.-D. Park, Y.-J. Suh, and S. Jeon, “Design and implementation of monitoring system for breathing and heart rate pattern using WiFi signals,” in 2018 15th IEEE Annual Consumer Communications & Networking Conference (CCNC). IEEE, Jan. 2018, pp. 1–7. [10] P.Hillyard,A.Luong,A.S.Abrar,N.Patwari,K.Sundar, R. Farney, J. Burch, C. A. Porucznik, and S. H. Pollard,
Publisher Copyright:
© 2021 IEEE.
Funding
VI. CONCLUSIONS In this paper, we show that robust breathing rate estimation from CSI relies on careful selection of the best CSI component, especially in the delay domain. To this end, we introduce a dominant path-based CSI amplitude calibration method and a linear component-based CSI phase calibration method for preprocessing of the CSI data. The calibration methods combined with the delay domain filtering leads to a better CSI extraction compared to PhaseBeat and its variants.Furthermore, we show that the breathing rate can be estimated directly from calibrated complex-valued CSI or CIR. Compared to observing only the phase values, the estimation from complex-valued CSI achieves the highest accuracy. ACKNOWLEDGMENT This research has been kindly supported by the Swiss National Science Foundation under Grant-ID 182621. REFERENCES [1] S. Rolfe, “The importance of respiratory rate monitor-ing,” British Journal of Nursing, vol. 28, no. 8, pp. 504– 508, Apr. 2019. [2] S. R. Pandi-Perumal, D. W. Spence, and A. S. Ba-Hammam, “Polysomnography: An overview,” in Primary Care Sleep Medicine, J. F. Pagel and S. R. Pandi-Perumal, Eds. Springer New York, 2014, pp. 29–42. [3] S.Costanzo,“Software-definedDopplerradarsensorfor human breathing detection”, Sensors, vol. 19, no. 14, p. 3085, Jul. 2019. [4] A. Droitcour, O. Boric-Lubecke, and G. Kovacs, “Signal-to-Noise Ratio in Doppler radar system for heart and respiratory rate measurements”, IEEE Transactions on Microwave Theory and Techniques, vol. 57, no. 10, pp. 2498–2507, Oct. 2009. [5] L. Anitori, A. de Jong, and F. Nennie, “FMCW radar for life-sign detection”, in 2009 IEEE Radar Conference. IEEE, 2009, pp. 1–6. [6] Z. Peng, J. M. Munoz-Ferreras, Y. Tang, C. Liu, R. Gomez-Garcia, L. Ran, and C. Li, “A portable FMCW interferometry radar with programmable Low-IF archi-tecture for localization, ISAR imaging, and vital sign tracking,” IEEE Transactions on Microwave Theory and Techniques, vol. 65, no. 4, pp. 1334–1344, Apr. 2017. [7] J. Liu, Y. Wang, Y. Chen, J. Yang, X. Chen, and J. Cheng, “Tracking vital signs during sleep leveraging off-the-shelf wifi,” in Proceedingsof the 16th ACM International Symposium on Mobile Ad Hoc Networking and Com-puting, ser. MobiHoc ’15. Association for Computing Machinery, 2015, p. 267276. [8] Y. Ma, G. Zhou, and S. Wang, “WiFi sensing with channel state information: A survey,” ACM Computing Surveys, vol. 52, no. 3, pp. 1–36, Jul. 2019. [9] S. Lee, Y.-D. Park, Y.-J. Suh, and S. Jeon, “Design and implementation of monitoring system for breathing and heart rate pattern using WiFi signals,” in 2018 15th IEEE Annual Consumer Communications & Networking Conference (CCNC). IEEE, Jan. 2018, pp. 1–7. [10] P.Hillyard,A.Luong,A.S.Abrar,N.Patwari,K.Sundar, R. Farney, J. Burch, C. A. Porucznik, and S. H. Pollard,
Keywords
- Channel state information
- OFDM amplitude calibration
- OFDM phase calibration
- Vital signs monitoring
- WiFi OFDM sensing
Fingerprint
Dive into the research topics of 'ComplexBeat: Breathing Rate Estimation from Complex CSI'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver