Abstract
This document presents a preliminary solution to Common exercise x. The exercise is solved by writing a mfile in MatLab. Appendix A provides a table with the requested calculations results, with:
Orient Orientation
Pin calculated internal pressure
err Pin error in calculated internal pressure
G1 flow through opening first floor south
G2 flow through opening first floor north
G3 flow through opening second floor south
G4 flow through opening second floor north
G5 flow through opening roof small pitch
G6 flow through opening roof large pitch
xin absolute humidity inside
cond condensation deposit ion roof as percentage of moisture production
E vent ventilation energy amount (transmission losses are not calculated)
A positive airflow means an airflow from external into the building.
Appendix B provided the Matlab files.
Original language | English |
---|---|
Title of host publication | Whole building heat, air and moisture transfer : IEA ECBCS Annex 41, working meeting, Trondheim |
Publication status | Published - 2005 |
Event | Whole building heat, air and moisture transfer : IEA ECBCS Annex 41, 4th working meeting, Trondheim - Duration: 26 Oct 2005 → 28 Oct 2005 |
Conference
Conference | Whole building heat, air and moisture transfer : IEA ECBCS Annex 41, 4th working meeting, Trondheim |
---|---|
Period | 26/10/05 → 28/10/05 |