Abstract
A review with 9 refs. The effect of process parameters and microstructure of preforms, on infiltration time, and relative composite d. was studied. High homogeneous composite d. does not coincide with high infiltration rates.,. Three-point bending strength of the composites indicated plastic fracture characteristics as long as the fiber-matrix interface was optimal. Addnl., some general properties and applications of the composites are presented. [on SciFinder (R)]
Original language | Dutch |
---|---|
Pages (from-to) | 287, 290-293 |
Number of pages | 6 |
Journal | KGK, Tijdschrift voor Klei, Glas en Keramiek |
Volume | 15 |
Issue number | 11 |
Publication status | Published - 1994 |