Analogy between temperature-dependent and concentration-dependent bacterial killing

C. Neef, S.A. Gils, van, W.L. IJzerman

    Research output: Contribution to journalArticleAcademicpeer-review

    6 Citations (Scopus)
    1 Downloads (Pure)

    Abstract

    In this article an analogy between temperature-dependent and concentration-dependent bacterial killing is described. The validation process of autoclaves uses parameters such as reduction rate constant k, decimal reduction time D and resistance coefficient z from an imaginary microorganism to describe the sterilization process. Total lethality of the process is calculated as the integral of the lethality (a function of the temperature) over time. In the case of concentration-dependent killing—i.e. using antibiotic drugs—the k-value is not necessarily a constant; it is the difference between growth and killing of the microorganism. Equations are derived for the decimal reduction time D and resistance coefficient z. Pharmacodynamic models of tobramycin, ciprofloxacin and ceftazidime are used to demonstrate that there is an optimal concentration for all three drugs: ..., ... and ... .
    Original languageEnglish
    Pages (from-to)529-549
    Number of pages21
    JournalComputers in Biology and Medicine
    Volume32
    Issue number6
    DOIs
    Publication statusPublished - 2002

    Fingerprint

    Dive into the research topics of 'Analogy between temperature-dependent and concentration-dependent bacterial killing'. Together they form a unique fingerprint.