Abstract
A method to asses the accuracy of a linear thermoacoustic model is proposed and applied
over a wide operating range of burner, equivalence ratio and flow velocity. In order to do
this, an intuitive quality measure is derived, which is able to quantify the discrepancy between
model and experiment. The presented method provides further insight into the overall model
performance, and the variation from case to case. It is shown that the linear model provides
an accurate prediction for 74% of the data points, with an average frequency error of 4.7%. In
addition, the method can be used as an effective tool for model comparison and optimization.
| Original language | English |
|---|---|
| Title of host publication | Proceeding of the 19th International Congress on Sound & Vibration (ICSV 19), 8-12 July 2012, Vilnius, Lithuania |
| Publisher | International Institute of Acoustics and Vibration (IIAV) |
| Publication status | Published - 2012 |
| Event | 19th International Congress on Sound and Vibration, ICSV 2012 - Vilnius, Lithuania Duration: 8 Jul 2012 → 12 Jul 2012 http://www.iiav.org/icsv19/ |
Conference
| Conference | 19th International Congress on Sound and Vibration, ICSV 2012 |
|---|---|
| Abbreviated title | ICSV 19 |
| Country/Territory | Lithuania |
| City | Vilnius |
| Period | 8/07/12 → 12/07/12 |
| Internet address |
Fingerprint
Dive into the research topics of 'Accuracy of a linear thermoacoustic model for (in)stability prediction of a large experimental dataset'. Together they form a unique fingerprint.Cite this