A positive association between postpartum electrohysterography parameters and blood loss after vaginal delivery: A prospective study

Maria Wilhelmina Elisabeth Frenken (Corresponding author), Daisy Adriana Anne-Jan van der Woude, Bettine Geertrude van Willigen, Jeanne Petra Dieleman, Swan Gie Oei, Judith Octavia Elisabeth Helena van Laar

Research output: Contribution to journalArticleAcademicpeer-review

10 Downloads (Pure)

Abstract

Introduction: The postpartum period can be complicated by hemorrhage, frequently caused by uterine atony. Electrohysterography, allowing continuous monitoring of uterine activity, may be a promising alternative for early detection of uterine atony, and thereby contribute to the prevention of postpartum hemorrhage. Associations between electrohysterographic parameters postpartum and total blood loss were studied. Methods: In this prospective explorative study, women were included with a vaginal delivery between 36+0 and 42+0 weeks of gestation. Linear regression analysis was used to describe the association between electrohysterographic parameters (i.e. area under the contraction curve (AUC) total (in arbitrary units), AUC from baseline (in arbitrary units), maximum amplitude (in arbitrary units) and baseline tone (in arbitrary units)) and total blood loss (in mL) during the first 30 min postpartum. Results: In total, 25 women were included for analysis, of whom three had postpartum hemorrhage. A moderate positive linear correlation was found between the logarithmically transformed total blood loss and the AUC total (r = 0.44, p = 0.03), AUC from baseline (r = 0.43, p = 0.03) and baseline tone (r = 0.43, p = 0.03). There was no significant linear correlation between the logarithmically transformed total blood loss and maximum amplitude. Explorative analysis revealed a significantly higher AUC total, AUC from baseline and baseline tone in women with postpartum hemorrhage compared to women without postpartum hemorrhage. (p = 0.02, p = 0.02 and p = 0.03, respectively). Discussion: There is a moderate positive correlation between the logarithmically transformed total blood loss and the AUC total, AUC from baseline and baseline tone. Also, these parameters were all significantly higher in women with postpartum hemorrhage compared to women without postpartum hemorrhage.

Original languageEnglish
Pages (from-to)11-19
Number of pages9
JournalPlacenta
Volume160
DOIs
Publication statusPublished - Feb 2025

Bibliographical note

Publisher Copyright:
© 2024 The Authors

Keywords

  • Electrohysterography
  • Electromyography
  • Postpartum hemorrhage
  • Third stage of labor
  • Uterine activity
  • Uterine contractions

Fingerprint

Dive into the research topics of 'A positive association between postpartum electrohysterography parameters and blood loss after vaginal delivery: A prospective study'. Together they form a unique fingerprint.

Cite this