If you made any changes in Pure these will be visible here soon.

Research Output 1987 2020

Filter
Article
2 Citations (Scopus)
1 Downloads (Pure)

A broadband method of quantifying phase synchronization for discriminating seizure EEG signals

Wang, L., Long, X., Aarts, R. M., van Dijk, J. P. & Arends, J. B. A. M., 20 Jun 2019, In : Biomedical Signal Processing and Control. 52, p. 371-383 13 p.

Research output: Contribution to journalArticleAcademicpeer-review

Electroencephalography
Synchronization
Seizures
Recurrence
Brain
7 Citations (Scopus)
50 Downloads (Pure)

A comparison of probabilistic classifiers for sleep stage classification

Fonseca, P., Den Teuling, N., Long, X. & Aarts, R. M., 15 May 2018, In : Physiological Measurement. 39, 5, 15 p., 055001.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Sleep Stages
Obstructive Sleep Apnea
Classifiers
Sleep
Polysomnography

A low-cost, lightweight, flat and very-high-efficiency loudspeaker system for low frequencies

Aarts, R. M., Ouweltjes, O. & Schobben, D. W. E., 2005, In : NAG-Journaal. 174, March 2005, p. 1-4 4 p.

Research output: Contribution to journalArticleAcademicpeer-review

loudspeakers
low frequencies
acoustics
transducers
cones
3 Citations (Scopus)

A method to adapt thoracic impedance based on chest geometry and composition to assess congestion in heart failure patients

Cuba-Gyllensten, I., Gastelurrutia, P., Bonomi, A. G., Riistama, J., Bayes-Genis, A. & Aarts, R. M., 1 Jun 2016, In : Medical Engineering & Physics. 38, 6, p. 538-546 9 p.

Research output: Contribution to journalArticleAcademicpeer-review

Electric Impedance
Thorax
Heart Failure
Geometry
Fluids
4 Citations (Scopus)
57 Downloads (Pure)

Analytic expressions and approximations for the on-axis, aberration-free Rayleigh and Debye integral in the case of focusing fields on a circular aperture

Aarts, R. M., Braat, J. J. M., Dirksen, P., Haver, van, S., Heesch, van, C. M. & Janssen, A. J. E. M., 2008, In : Journal of the European Mathematical Society. 3, p. 08039-1/10

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Aberrations
Aberration
Rayleigh
Diffraction
Acoustics
42 Citations (Scopus)
308 Downloads (Pure)

Analyzing respiratory effort amplitude for automated sleep stage classification

Long, X., Foussier, J., Fonseca, P., Haakma, R. & Aarts, R. M., 2014, In : Biomedical Signal Processing and Control. 14, p. 197-205 9 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Sleep Stages
Sleep
REM Sleep
Eye movements
Tidal Volume
1 Citation (Scopus)
9 Downloads (Pure)

An electro-acoustic implementation of Tibetan bowls : acoustics and perception

Aarts, R. M., Ouweltjes, O. & Bulut, M., 2014, In : Noise & Vibration Worldwide. 45, 1, p. 12-23 12 p.

Research output: Contribution to journalArticleAcademicpeer-review

Acoustics
Acoustic waves
acoustics
Electroencephalography
Skin
16 Citations (Scopus)
102 Downloads (Pure)

A novel low-complexity post-processing algorithm for precise QRS localization

Fonseca, P., Aarts, R. M., Foussier, J. & Long, X., 2014, In : SpringerPlus. 3, 13 p., 376.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Processing
Jitter
Detectors
Electrocardiography
Sampling
7 Citations (Scopus)
70 Downloads (Pure)

A novel wearable vest for tracking pulmonary congestion in acutely decompensated heart failure : pilot study

Cuba Gyllensten, I., Gastelurrutia, P., Riistama, J., Aarts, R. M., Nunez, J., Lupon, J. & Bayes-Genis, A., 2014, In : International Journal of Cardiology. 177, p. 199-201 3 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
39 Citations (Scopus)

Approximation of the Struve function H1 occurring in impedance calculations

Aarts, R. M. & Janssen, A. J. E. M., 2003, In : Journal of the Acoustical Society of America. 113, 5, p. 2635-2637 3 p.

Research output: Contribution to journalArticleAcademicpeer-review

impedance
radiators
pistons
approximation
audio frequencies
10 Citations (Scopus)

A real-time speech-music discriminator

Aarts, R. M. & Dekkers, R. T., 1 Dec 1999, In : Journal of the Audio Engineering Society. 47, 9, p. 720-725 6 p.

Research output: Contribution to journalArticleAcademicpeer-review

Discriminators
Musical instruments
Networks (circuits)
Music
1 Downloads (Pure)

Arterial path selection to measure pulse wave velocity as a surrogate marker of blood pressure

Radha, M., Zhang, G., Gelissen, J., de Groot, K., Haakma, R. & Aarts, R. M., 8 Feb 2017, In : Biomedical Physics & Engineering Express. 3, 1, p. 1-10 10 p., 015022.

Research output: Contribution to journalArticleAcademicpeer-review

Pulse Wave Analysis
Biomarkers
Blood Pressure
Fingers
Calibration
240 Citations (Scopus)
286 Downloads (Pure)

A survey of stimulation methods used in SSVEP-based BCIs

Zhu, D., Bieger, J., Garcia Molina, G. & Aarts, R. M., 2010, In : Computational Intelligence and Neuroscience. 2010, p. 1-12 12 p., 702357.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Visual Evoked Potentials
Bioelectric potentials
Brain-Computer Interfaces
Brain computer interface
Computer Systems
9 Citations (Scopus)
44 Downloads (Pure)

Atrial fibrillation detection using a novel cardiac ambulatory monitor based on photo-plethysmography at the wrist

Bonomi, A. G., Schipper, F., Eerikäinen, L. M., Margarito, J., van Dinther, R., Muesch, G., de Morree, H. M., Aarts, R. M., Babaeizadeh, S., McManus, D. D. & Dekker, L. R. C., 1 Aug 2018, In : Journal of the American Heart Association. 7, 15, 17 p., e009351.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Plethysmography
Wrist
Atrial Fibrillation
Electric Countershock
Electrocardiography
19 Citations (Scopus)
59 Downloads (Pure)

Atrial fibrillation detection using photo-plethysmography and acceleration data at the wrist

Bonomi, A. G., Schipper, F., Eerikäinen, L. M., Margarito, J., Aarts, R. M., Babaeizadeh, S., de Morree, H. M. & Dekker, L. R. C., 2016, In : Computing in Cardiology. 43, p. 277-280

Research output: Contribution to journalArticleAcademic

Open Access
File
Photoplethysmography
Plethysmography
Wrist
Electrocardiography
Atrial Fibrillation

Authors' reply to a comment on "Which of the two digital audio systems best matches the quality of the analog system"

Woszczyk, W., Engel, J., Usher, J., Aarts, R. M. & Reefman, D., 2009, In : Journal of the Audio Engineering Society. 57, 10, p. 833-834 2 p.

Research output: Contribution to journalArticleAcademicpeer-review

Audio systems
1 Citation (Scopus)
1 Downloads (Pure)

Automated preterm infant sleep staging using capacitive electrocardiography

Werth, J., Serteyn, A., Andriessen, P., Aarts, R. & Long, X., 4 Jun 2019, In : Physiological Measurement. 40, 5, 14 p., 055003.

Research output: Contribution to journalArticleAcademicpeer-review

Electrocardiography
Premature Infants
Sleep
Adhesives
Electrodes
1 Downloads (Pure)

Blind cancellation of stereo-base widening

Ven, van de, H. H., Aarts, R. M. & Sommen, P. C. W., 2007, In : Journal of the Audio Engineering Society. 55, 4, p. 227-235 9 p.

Research output: Contribution to journalArticleAcademicpeer-review

Stereophonic recordings
Deterioration
9 Citations (Scopus)
164 Downloads (Pure)

Cardiorespiratory sleep stage detection using conditional random fields

Fonseca, P., den Teuling, N. G. P., Long, X. & Aarts, R. M., 1 Jul 2017, In : IEEE Journal of Biomedical and Health Informatics. 21, 4, p. 956-966 11 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Sleep Stages
Healthy Volunteers
Sleep
Classifiers
Plethysmography
11 Citations (Scopus)
2 Downloads (Pure)
spherical caps
loudspeakers
acoustics
radiation
baffles
4 Citations (Scopus)
10 Downloads (Pure)

Comparison between electrocardiogram- and photoplethysmogram-derived features for atrial fibrillation detection in free-living conditions

Eerikäinen, L. M., Bonomi, A. G., Schipper, F., Dekker, L. R. C., Vullings, R., de Morree, H. M. & Aarts, R. M., 8 Aug 2018, In : Physiological Measurement. 39, 8, 084001.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Photoplethysmography
Social Conditions
Electrocardiography
Atrial Fibrillation
Entropy
2 Citations (Scopus)
1 Downloads (Pure)

Comparison of cardiac magnetic resonance imaging and bio-impedance spectroscopy for the assessment of fluid displacement induced by external leg compression

Saporito, S., Dovancescu, S., Herold, I. H. F., van den Bosch, H. C. M., van Assen, H. C., Aarts, R. M., Korsten, H. H. M. & Mischi, M., 1 Jan 2017, In : Physiological Measurement. 38, 1, p. 15-32 18 p.

Research output: Contribution to journalArticleAcademicpeer-review

Dielectric Spectroscopy
Magnetic resonance
Leg
Compaction
Thorax

Deep learning approach for ECG-based automated sleep state classification in preterm infants

Werth, J., Radha, M., Andriessen, P., Aarts, R. & Long, X., 1 Feb 2020, In : Biomedical Signal Processing and Control. 56, 10 p., 101663.

Research output: Contribution to journalArticleAcademicpeer-review

Electrocardiography
Premature Infants
Sleep
Learning
Network architecture
6 Citations (Scopus)
101 Downloads (Pure)

Derivation of an optimal directivity pattern for sweet spot widening in stereo sound reproduction

Ródenas, J. A., Aarts, R. M. & Janssen, A. J. E. M., 2003, In : Journal of the Acoustical Society of America. 113, 1, p. 267-278 12 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
directivity
loudspeakers
derivation
stereophonics
acoustics
2 Citations (Scopus)

Design of an experimental set-up to study the behavior of a flexible surgical instrument inside an endoscope

Khatait, J. P., Brouwer, D. M., Soemers, H. M. J. R., Aarts, R. G. K. M. & Herder, J. L., 3 Jul 2013, In : Journal of Medical Devices. 7, 3, 031004.

Research output: Contribution to journalArticleAcademicpeer-review

Endoscopy
Endoscopes
Surgical Instruments
Research Design
Friction
11 Citations (Scopus)
3 Downloads (Pure)

Detection of a spontaneous pulse in photoplethysmograms during automated cardiopulmonary resuscitation in a porcine model

Wijshoff, R. W. C. G. R., Sar, van der, T., Peeters, W. H., Bezemer, R., Aelen, P., Paulussen, I. W. F., Ordelman, S. C. M. A., Venema, A., Berkom, van, P. F. J., Aarts, R. M., Woerlee, P. H., Scheffer, G. J. & Noordergraaf, G. J., Nov 2013, In : Resuscitation. 84, 11, p. 1625-1632

Research output: Contribution to journalArticleAcademicpeer-review

Photoplethysmography
Cardiopulmonary Resuscitation
Pulse
Swine
Arterial Pressure
5 Citations (Scopus)
4 Downloads (Pure)

Detection of nocturnal slow wave sleep based on cardiorespiratory activity in healthy adults

Long, X., Fonseca, P., Aarts, R. M., Haakma, R., Rolink, J. & Leonhardt, S., 2017, In : IEEE Journal of Biomedical and Health Informatics. 21, 1, p. 123 - 133

Research output: Contribution to journalArticleAcademicpeer-review

Sleep
Polysomnography
Sleep Stages
Physiology
Artifacts
16 Citations (Scopus)

Direct-radiator loudspeaker systems with high BI

Vanderkooy, J., Boers, P. M. & Aarts, R. M., 1 Jul 2003, In : Journal of the Audio Engineering Society. 51, 7-8, p. 625-634 10 p.

Research output: Contribution to journalArticleAcademicpeer-review

Loudspeakers
Radiators
Prototype
13 Citations (Scopus)
4 Downloads (Pure)

EEG analysis of seizure patterns using visibility graphs for detection of generalized seizures

Wang, L., Long, X., Arends, J. B. A. M. & Aarts, R. M., 1 Oct 2017, In : Journal of Neuroscience Methods. 290, p. 85-94 10 p.

Research output: Contribution to journalArticleAcademicpeer-review

Electroencephalography
Seizures
Intellectual Disability
Benchmarking
Entropy
4 Downloads (Pure)
Electroencephalography
Intellectual Disability
Seizures
Population
Detectors
29 Downloads (Pure)
Open Access
File
Electroencephalography
Bandpass filters
Electrocardiography
Discrete Fourier transforms
Signal processing
7 Citations (Scopus)
69 Downloads (Pure)
Open Access
File
Multilevel Analysis
Sleep
Sleep Stages
Demography
Physiology
1 Citation (Scopus)
24 Downloads (Pure)

Efficient approximation of the Struve functions Hn occurring in the calculation of sound radiation quantaties

Aarts, R. M. & Janssen, A. J. E. M., Dec 2016, In : Journal of the Acoustical Society of America. 140, 6, p. 4154-4160 7 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File

Efficient resonant loudspeakers with large form-factor design freedom

Aarts, R. M., Nieuwendijk, J. A. M. & Ouweltjes, O., 2006, In : Journal of the Audio Engineering Society. 54, 10, p. 940-953 14 p.

Research output: Contribution to journalArticleAcademicpeer-review

Loudspeakers
Frequency response
Cones
Acoustics
Pipe
8 Citations (Scopus)

Efficient resonant loudspeakers with large form-factor design freedom

Aarts, R. M., Nieuwendijk, J. A. M. & Ouweltjes, O., 1 Oct 2006, In : Journal of the Audio Engineering Society. 54, 10, p. 940-953 14 p.

Research output: Contribution to journalArticleAcademicpeer-review

Loudspeakers
loudspeakers
form factors
sound pressure
Acoustic waves
20 Citations (Scopus)
100 Downloads (Pure)

Efficient tracking of the cross-correlation coefficient

Aarts, R. M., Irwan, R. & Janssen, A. J. E. M., 2002, In : IEEE Transactions on Speech and Audio Processing. 10, 6, p. 391-402 12 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
correlation coefficients
cross correlation
Audio recordings
Processing
time signals
67 Downloads (Pure)

Enhancement of the comb filtering selectivity using iterative moving average for periodic waveform and harmonic elimination

Ferreira, J. L., Wu, Y. & Aarts, R. M., 1 Feb 2018, In : Journal of Healthcare Engineering. 2018, 14 p., 7901502.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Comb and Wattles
Electroencephalography
Comb filters
Artifacts
Bandwidth
1 Citation (Scopus)
79 Downloads (Pure)

Erratum: Measuring dissimilarity between respiratory effort signals based on uniform scaling for sleep staging (2014 Physiol. Meas. 35 2539)

Long, X., Yang, J., Weysen, T., Haakma, R., Foussier, J., Fonseca, P. & Aarts, R. M., 2015, In : Physiological Measurement. 36, 3, p. 625-625 1 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Sleep
Respiration
Manuscripts
Sleep Stages
Typesetting
5 Citations (Scopus)
92 Downloads (Pure)

Estimating actigraphy from motion artifacts in ECG and respiratory effort signals

Fonseca, P., Aarts, R. M., Long, X., Rolink, J. & Leonhardt, S., 1 Jan 2016, In : Physiological Measurement. 37, 1, p. 67-82 16 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Plethysmography
Actigraphy
Electrocardiography
Inductance
Artifacts
1 Citation (Scopus)

Estimating blood pressure trends and the nocturnal dip from photoplethysmography

Radha, M., de Groot, K., Rajani, N., Wong, C. C. P., Kobold, N., Vos, V., Fonseca, P., Mastellos, N., Wark, P. A., Velthoven, N., Haakma, R. & Aarts, R. M., 25 Feb 2019, In : Physiological Measurement. 40, 2, 14 p., 025006.

Research output: Contribution to journalArticleAcademicpeer-review

Photoplethysmography
Blood pressure
Blood Pressure
Long-Term Memory
Short-Term Memory
5 Citations (Scopus)
Loudspeakers
Velocity distribution
Radiators
Polynomials
Acoustic waves
3 Citations (Scopus)
22 Downloads (Pure)

Finger and forehead photoplethysmography-derived pulse-pressure variation and the benefits of baseline correction

Sun, S., Peeters, W., Bezemer, R., Long, X., Paulussen, I. W. F., Aarts, R. M. & Noordergraaf, G. J., 1 Feb 2019, In : Journal of Clinical Monitoring and Computing. 33, 1, p. 65–75

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Photoplethysmography
Forehead
Fingers
Pulse
Blood Pressure
58 Downloads (Pure)

Gradient artefact correction and evaluation of the EEG recorded simultaneously with fMRI data using optimised moving-average.

Ferreira, J. L., Wu, Y., Besseling, R. M. H., Lamerichs, R. M. J. N. & Aarts, R. M., Jun 2016, In : Journal of Medical Engineering. 2016, p. 1-17 9614323.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
Electroencephalography
Magnetic resonance imaging
Magnetic Resonance Imaging
1 Downloads (Pure)

Gradient artefact modelling using a set of sinusoidal waveforms for EEG correction during continuous fMRI

Ferreira, J. L., Cluitmans, P. J. M. & Aarts, R. M., 2013, In : Signal Processing Research. 2, 2, p. 39-48 10 p.

Research output: Contribution to journalArticleAcademicpeer-review

electroencephalography
artifacts
waveforms
gradients
brain
17 Citations (Scopus)

High-efficiency low-Bl loudspeakers

Aarts, R. M., 1 Jul 2005, In : Journal of the Audio Engineering Society. 53, 7-8, p. 579-592 14 p.

Research output: Contribution to journalArticleAcademicpeer-review

Loudspeakers
loudspeakers
Magnets
magnets
Sound reproduction
5 Citations (Scopus)
81 Downloads (Pure)

Hybrid optical unobtrusive blood pressure measurements

Zhang, G., Shan, C., Kirenko, I., Long, X. & Aarts, R. M., 1 Jul 2017, In : Sensors. 17, 7, p. 1-15 15 p., 1541.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
blood pressure
Photoplethysmography
Blood pressure
pressure measurement
Pressure measurement
18 Citations (Scopus)
1 Downloads (Pure)

Low-complexity intrauterine pressure estimation using the Teager energy operator on electrohysterographic recordings

Rooijakkers, M. J., Rabotti, C., Oei, S. G., Aarts, R. M. & Mischi, M., 2014, In : Physiological Measurement. 35, 7, p. 1215-1228

Research output: Contribution to journalArticleAcademicpeer-review

Mathematical operators
Pressure
Uterine Monitoring
Monitoring
Signal analysis
6 Citations (Scopus)

Low-complexity tracking and estimation of frequency and amplitude of sinusoids

Aarts, R. M., 1 Jul 2004, In : Digital Signal Processing: A Review Journal. 14, 4, p. 372-378 7 p.

Research output: Contribution to journalArticleAcademicpeer-review

Low Complexity
Non-stationary Signal
Costs
Stationary States
Square root
5 Citations (Scopus)
57 Downloads (Pure)

Measures of cardiovascular autonomic activity in insomnia disorder : a systematic review

Nano, M., Fonseca, P., Vullings, R. & Aarts, R. M., 23 Oct 2017, In : PLoS ONE. 12, 10, p. 1-31 0186716.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
systematic review
Sleep Initiation and Maintenance Disorders
Electroencephalography
Association reactions
heart rate
20 Citations (Scopus)
10 Downloads (Pure)

Measuring dissimilarity between respiratory effort signals based on uniform scaling for sleep staging

Long, X., Yang, J., Weysen, T., Haakma, R., Foussier, J., Fonseca, P. & Aarts, R. M., 2014, In : Physiological Measurement. 35, 12, p. 2529-2542

Research output: Contribution to journalArticleAcademicpeer-review

Sleep
REM Sleep
Sleep Stages
Eye movements
Light