Marcel C.M. Rutten

dr.ir.

  • 2364 Citations
1992 …2020
If you made any changes in Pure these will be visible here soon.

Research Output 1992 2020

2012
2 Downloads (Pure)

Novel strategy of the determination of mechanical properties of human carotid atherosclerotic plaques

Boekhoven, R. W., Lopata, R. G. P., Rutten, M. C. M., van Sambeek, M. R. H. M. & Vosse, van de, F. N., 2012, Proceedings of the ASME 2012 Summer Bioengineering Conference (SBC 2012), 20-23 June 2012, Fajardo, Puerto Rico, USA. New York: American Society of Mechanical Engineers, 2 p. SBC2012-80669

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

Mechanical properties
27 Citations (Scopus)
3 Downloads (Pure)

Periprocedural variations of platelet reactivity during elective percutaneous coronary intervention

Mangiacapra, F., Bartunek, J., Bijnens, N., Peace, A. J., Dierickx, J., Bailleul, E., Di Serafino, L., Pyxaras, SA., Fraeyman, A., Meeus, P., Rutten, M. C. M., Bruyne, de, B., Wijns, W., Vosse, van de, F. N. & Barbato, E., 2012, In : Journal of Thrombosis and Haemostasis. 10, 12, p. 2452-2461 10 p.

Research output: Contribution to journalArticleAcademicpeer-review

Percutaneous Coronary Intervention
Blood Platelets
E-Selectin
clopidogrel
Myocardial Infarction
1 Downloads (Pure)

Pump flow estimation in the HeartAssist5, HeartMatell and HeartWare VADs

Pennings, K. A. M. A., Martina, J. R., Rodermans, B. F. M., Vosse, van de, F. N., Lahpor, J. R., Mol, de, B. A. J. M. & Rutten, M. C. M., 2012.

Research output: Contribution to conferencePoster

12 Citations (Scopus)
58 Downloads (Pure)
Open Access
File
Fiber Orientation
Fiber reinforced materials
Constitutive Model
Constitutive models
Parameter estimation
13 Citations (Scopus)

Thermal flow sensors on flexible substrates for minimally invasive medical instruments

Mimoun, B., van der Horst, A., van der Voort, D., Rutten, M., van de Vosse, F. N. & Dekker, R., 2012, Proceedings of IEEE Sensors. Piscataway: Institute of Electrical and Electronics Engineers, 4 p. 6411429

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

Thermopiles
Sensors
Substrates
Electric heating elements
Seebeck coefficient
2011
24 Citations (Scopus)

A generic constitutive model for the passive porcine coronary artery

Broek, van den, C. N., Horst, van der, A., Rutten, M. C. M. & Vosse, van de, F. N., 2011, In : Biomechanics and Modeling in Mechanobiology. 10, 2, p. 249-258 10 p.

Research output: Contribution to journalArticleAcademicpeer-review

Coronary Artery
Arteries
Constitutive Model
Constitutive models
Coronary Vessels
3 Citations (Scopus)
68 Downloads (Pure)

A method to increase the pulsatility in hemodynamic variables in an LVAD supported human circulation system

Bozkurt, S., Pennings, K. A. M. A., Schampaert, S., Vosse, van de, F. N. & Rutten, M. C. M., 2011, Proceedings of the International Conference on Advancements of Medicine and Health Care through Technology, 29-08-2011-02-09-2011, Cluj-Napoca, Romania. Vlad, S. & Ciupa, R. V. (eds.). Berlin: Springer, p. 328-331 (IFMBE Proceedings; vol. 36).

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

Open Access
File
Left ventricular assist devices
Hemodynamics
Cardiovascular system
2 Citations (Scopus)
1 Downloads (Pure)
Pulsatile flow
sensors
Sensors
Thermopiles
tubes
38 Citations (Scopus)

An ex vivo platform to simulate cardiac physiology: A new dimension for therapy development and assessment

de Hart, J., Weger, A., van Tuijl, S., Stijnen, J. M. A., van den Broek, C. N., Rutten, M. C. M. & de Mol, B. A., 1 Jun 2011, In : International Journal of Artificial Organs. 34, 6, p. 495-505 11 p.

Research output: Contribution to journalArticleAcademicpeer-review

Physiology
Hemodynamics
Equipment and Supplies
Computer Simulation
Swine

Aortic valve function under assistance of a physiologically controlled CF-LVAD

Bozkurt, S., Vosse, van de, F. N. & Rutten, M. C. M., 2011.

Research output: Contribution to conferencePoster

3 Downloads (Pure)
29 Citations (Scopus)

Continuous-flow cardiac assistance : effects on aortic valve function in a mock loop

Tuzun, E., Rutten, M. C. M., Dat, M., Kadipasaoglu, C., Vosse, van de, F. N. & Mol, de, B. A. J. M., 2011, In : Journal of Surgical Research. 171, 2, p. 443-447

Research output: Contribution to journalArticleAcademicpeer-review

Heart-Assist Devices
Aortic Valve
Cardiovascular System
Stroke Volume
Arterial Pressure

Contrast-free blood flow velocity profile measurement with ultrasound in real-time

Koutsouridis, G. G., Bijnens, N., Geldermalsen, van, S., Brands, P. J., Vosse, van de, F. N. & Rutten, M. C. M., 2011.

Research output: Contribution to conferencePoster

1 Citation (Scopus)

Contrast-free blood flow velocity profile measurement with ultrasound in real-time

Koutsouridis, G. G., Bijnens, N., Geldermalsen, van, S., Brands, P. J., Vosse, van de, F. N. & Rutten, M. C. M., 2011, ASME 2011 Summer Bioengineering Conference (SBC 2011), 22-25 June 2011, Famington, Pennsylvania, USA.

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

blood flow
flow velocity
velocity distribution

Elliptic varying LVAD speed over a cardiac cycle

Bozkurt, S., Pennings, K. A. M. A., Vosse, van de, F. N. & Rutten, M. C. M., 2011, p. A46-A46.

Research output: Contribution to conferencePoster

Diastole
Cardiovascular Models
Systole
Cardiovascular System
Aortic Valve
12 Citations (Scopus)

In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous

Schampaert, S., Veer, van 't, M., Vosse, van de, F. N., Pijls, N. H. J., Mol, de, B. A. J. M. & Rutten, M. C. M., 2011, In : Artificial Organs. 35, 9, p. 893-901 9 p.

Research output: Contribution to journalArticleAcademicpeer-review

Balloons
Cardiac Output
Cardiogenic Shock
Hemodynamics
Pumps

In-vivo real-time contrast-free ultrasonic blood flow velocity profile measurement

Koutsouridis, G. G., Bijnens, N., Brands, P. J., Vosse, van de, F. N. & Rutten, M. C. M., 2011.

Research output: Contribution to conferencePoster

Modeling coronary hemodynamics in health and disease

Horst, van der, A., Broek, van den, C. N., Rutten, M. C. M. & Vosse, van de, F. N., 2011, Proceedings of the 6th International Symposium on Biomechanics in Vascular Biology and Cardiovascular Disease, 14-15 April 2011, Rotterdam, The Netherlands. A. Horrevoets, J. Wentzel, F. G. (ed.).

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

Hemodynamics
Health
47 Downloads (Pure)

Modeling coronary hemodynamics in health and disease

Horst, van der, A., Boogaard, F. L., Veer, van 't, M., Rutten, M. C. M. & Vosse, van de, F. N., 2011.

Research output: Contribution to conferencePoster

Open Access
File
43 Downloads (Pure)

Physiological control of an LVAD to control aortic valve motion in the human cardiovascular system

Bozkurt, S., Pennings, K. A. M. A., Schampaert, S., Vosse, van de, F. N. & Rutten, M. C. M., 2011, p. 682-682.

Research output: Contribution to conferencePoster

Open Access
File
Cardiovascular system
2 Downloads (Pure)

Real-time contrast-free ultrasonic blood flow velocity profile measurement

Koutsouridis, G. G., Bijnens, N., Brands, P. J., Vosse, van de, F. N. & Rutten, M. C. M., 2011.

Research output: Contribution to conferencePoster

6 Citations (Scopus)
Shear deformation
Hot Temperature
Wire
Pressure
Temperature

The use of wavelets for wall removal and scatter enhancement in ultrasound blood velocity profile measurements

Bijnens, N., Koutsouridis, G. G., Brands, P. J., Rutten, M. C. M. & Vosse, van de, F. N., 2011, Proceedings of the ASME 2011 Summer Bioengineering Conference (SBC 2011), 22-25 June 2011, Farmington, Pennsylvania, USA.

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

35 Citations (Scopus)
1 Downloads (Pure)

Towards noninvasive blood pressure assessment in arteries by using ultrasound

Beulen, B., Bijnens, N., Koutsouridis, G. G., Brands, P. J., Rutten, M. C. M. & Vosse, van de, F. N., 2011, In : Ultrasound in Medicine and Biology. 37, 5, p. 788-797 10 p.

Research output: Contribution to journalArticleAcademicpeer-review

blood pressure
arteries
Arteries
waveforms
Blood Pressure
2010
2 Downloads (Pure)

A constitutive model to describe coronary vasoconstriction

Broek, van den, C. N., Nieuwenhuijzen, J., Rutten, M. C. M. & Vosse, van de, F. N., 2010.

Research output: Contribution to conferencePoster

Altered aortic root flow in LVAD supported hearts

Bozkurt, S., Rutten, M. C. M. & Vosse, van de, F. N., 2010.

Research output: Contribution to conferencePoster

7 Citations (Scopus)
1 Downloads (Pure)

Computational modelling of endoleak after endovascular repair of abdominal aortic aneurysms

Wolters, B. J. B. M., Rutten, M. C. M., Schurink, G. W. H. & Vosse, van de, F. N., 2010, In : International Journal for Numerical Methods in Biomedical Engineering. 26, 3, p. 322-335

Research output: Contribution to journalArticleAcademicpeer-review

Endoleak
Aneurysm
Computational Modeling
Abdominal Aortic Aneurysm
Repair
2 Downloads (Pure)

Fiber orientation in porcine coronaries, as described by the Holzapfel model, is fixed at physiological loading

Horst, van der, A., Broek, van den, C. N., Rutten, M. C. M. & Vosse, van de, F. N., 2010, Proceedings of the ASME 2011 Summer Bioengineering Conference (SBC 2011), 22-25 June 2011, Farmington, Pennsylvania, USA. R.M. Petterson, J. H. (ed.). United States, Farmington, Pennsylvania: American Society of Mechanical Engineers, p. SBC2010-19503-

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

swine
93 Downloads (Pure)

In situ tissue engineering of heart valves : an in vitro feasibility study

Ballotta, V., Driessen - Mol, A., Wijlaars, M. W., Rutten, M. C. M. & Baaijens, F. P. T., 2010.

Research output: Contribution to conferencePoster

Open Access
File
13 Citations (Scopus)
65 Downloads (Pure)

Perpendicular ultrasound velocity measurement by 2D cross-correlation of RF data: part B. Volume flow estimation in curved vessels

Beulen, B., Verkaik, A. C., Bijnens, N., Rutten, M. C. M. & Vosse, van de, F. N., 2010, In : Experiments in Fluids. 49, 6, p. 1219-1229

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
velocity measurement
Velocity measurement
cross correlation
vessels
Ultrasonics
18 Citations (Scopus)
71 Downloads (Pure)

Perpendicular ultrasound velocity measurement by 2D cross-correlation of RF-data. Part A: validation in a straight tube

Beulen, B., Bijnens, N., Rutten, M. C. M., Brands, P. J. & Vosse, van de, F. N., 2010, In : Experiments in Fluids. 49, 5, p. 1177-1186

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
velocity measurement
Velocity measurement
cross correlation
blood
Ultrasonics

Rotation enabled 2D ultrasonography on human atherosclerotic carotid artery

Boekhoven, R. W., Rutten, M. C. M., Sambeek, M. J. & Vosse, van de, F. N., 2010.

Research output: Contribution to conferencePoster

8 Downloads (Pure)

Towards a non-invasive ultrasound pressure assessment in large arteries

Koutsouridis, G. G., Beulen, B. W. A. M. M., Bijnens, N., Brands, P. J., Rutten, M. C. M. & Vosse, van de, F. N., 2010.

Research output: Contribution to conferencePoster

4 Citations (Scopus)
3 Downloads (Pure)

Wave propagation in thin-walled aortic analogues

Giannopapa, C. G., Kroot, J. M. B., Tijsseling, A. S., Rutten, M. C. M. & Vosse, van de, F. N., 2010, In : Journal of Fluids Engineering : Transactions of the ASME. 132, 2, p. 021104-1/6

Research output: Contribution to journalArticleAcademicpeer-review

Wave propagation
Analytical models
Numerical models
Blood
Flow rate
2009
34 Downloads (Pure)

A generic material model of the passive porcine coronary artery

Broek, van den, C. N., Horst, van der, A., Rutten, M. C. M. & Vosse, van de, F. N., 2009.

Research output: Contribution to conferencePoster

Open Access
File
Coronary Vessels
Swine
46 Citations (Scopus)
2 Downloads (Pure)

A mathematical model to evaluate control strategies for mechanical circulatory support

Cox, L. G. E., Loerakker, S., Rutten, M. C. M., Mol, de, B. A. J. M. & Vosse, van de, F. N., 2009, In : Artificial Organs. 33, 8, p. 593-603

Research output: Contribution to journalArticleAcademicpeer-review

Heart-Assist Devices
Theoretical Models
Mathematical models
Computer Simulation
Heart Ventricles
1 Downloads (Pure)

A mixed experimental-numerical estimation strategy to characterize arterial wall properties including residual strains

Horst, van der, A., Broek, van den, C. N., Rutten, M. C. M. & Vosse, van de, F. N., 2009, Proceedings of the ASME 2009 Summer Bioengineering Conference (SBC2009), 17-21 June 2009, United States, Squaw Valley, CA. New York: American Society of Mechanical Engineers, p. on-cd

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

15 Citations (Scopus)
1 Downloads (Pure)

A time-periodic approach for fluid-structure interaction in distensible vessels

Beulen, B. W. A. M. M., Rutten, M. C. M. & Vosse, van de, F. N., 2009, In : Journal of Fluids and Structures. 25, 5, p. 954-966

Research output: Contribution to journalArticleAcademicpeer-review

Fluid structure interaction
Incompressible flow
Pressure distribution
Wave propagation
Blood
1 Downloads (Pure)

Characterization of patients with continuous flow left ventricular assist devices

Martina, J. R., Rutten, M. C. M., Jonge, de, N., Mol, de, B. A. J. M. & Lahpor, J. R., 2009.

Research output: Contribution to conferencePoster

Heart-Assist Devices
18 Citations (Scopus)
1 Downloads (Pure)

Continuous infusion thermodilution for assessment of coronary flow: Theoretical background and in vitro validation

Veer, van 't, M., Geven, M. C. F., Rutten, M. C. M., Horst, van der, A., Aarnoudse, W. H., Pijls, N. H. J. & Vosse, van de, F. N., 2009, In : Medical Engineering & Physics. 31, 6, p. 688-694

Research output: Contribution to journalArticleAcademicpeer-review

Thermodilution
Catheters
Temperature
Qi
Coronary Circulation

Deformation controlled load application in heart valve tissue-engineering

Kortsmit, J., Rutten, M. C. M., Wijlaars, M. W. & Baaijens, F. P. T., 1 Dec 2009, Proceedings of the ASME Summer Bioengineering Conference 2009, SBC2009. New York: American Society of Mechanical Engineers, Vol. B. p. 1279-1280 2 p. SBC2009-206446

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

14 Citations (Scopus)

Deformation-controlled load application in heart valve tissue engineering

Kortsmit, J., Rutten, M. C. M., Wijlaars, M. W. & Baaijens, F. P. T., 2009, In : Tissue Engineering. Part C: Methods. 15, 4, p. 707-716

Research output: Contribution to journalArticleAcademicpeer-review

Heart Valves
Tissue Engineering
Tissue engineering
Bioreactors
Tissue
48 Citations (Scopus)
2 Downloads (Pure)

Dynamic Straining Combined with Fibrin Gel Cell Seeding Improves Strength of Tissue-Engineered Small-Diameter Vascular Grafts

Stekelenburg, M., Rutten, M. C. M., Snoeckx, L. H. E. H. & Baaijens, F. P. T., 2009, In : Tissue engineering. Part A. 15, 5, p. 1081-1089

Research output: Contribution to journalArticleAcademicpeer-review

Fibrin
Grafts
Blood Vessels
Gels
Tissue
18 Citations (Scopus)
99 Downloads (Pure)

Estimation of volume flow in curved tubes based on analytical and computational analysis of axial velocity profiles

Verkaik, A. C., Beulen, B. W. A. M. M., Bogaerds, A. C. B., Rutten, M. C. M. & Vosse, van de, F. N., 2009, In : Physics of Fluids. 21, 2, p. 023602-1/13 13 p., 023602.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
velocity distribution
tubes
computational fluid dynamics
dynamic models
Computational fluid dynamics

Load-induced aortic insufficiency in LVAD patients: a model study

Tuzun, E., Rutten, M. C. M., Vosse, van de, F. N. & Mol, de, B. A. J. M., 2009.

Research output: Contribution to conferencePoster

Mechanical properties of the porcine coronary artery

Broek, van den, C. N., Horst, van der, A., Rutten, M. C. M. & van de Vosse, F. N., 2009, Proceedings of the ASME 2009 Summer Bioengineering Conference (SBC2009), 17-21 June 2009, United States, Squaw Valley, CA. New York: American Society of Mechanical Engineers

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

13 Citations (Scopus)

Nondestructive and noninvasive assessment of mechanical properties in heart valve tissue engineering

Kortsmit, J., Driessen, N. J. B., Rutten, M. C. M. & Baaijens, F. P. T., 2009, In : Tissue engineering. Part A. 15, 4, p. 797-806

Research output: Contribution to journalArticleAcademicpeer-review

Heart Valves
Tissue Engineering
Tissue engineering
Tissue
Mechanical properties
21 Citations (Scopus)

Real time, non-invasive assessment of leaflet deformation in heart valve tissue engineering

Kortsmit, J., Driessen, N. J. B., Rutten, M. C. M. & Baaijens, F. P. T., 2009, In : Annals of Biomedical Engineering. 37, 3, p. 532-541

Research output: Contribution to journalArticleAcademicpeer-review

Tissue engineering
Tissue
Bioreactors
Time measurement
Numerical models