Department of Biomedical Engineering

Research Output

Article

An MR-compatible bicycle ergometer for in-magnet whole-body human exercise testing

Jeneson, J. A. L., Schmitz, J. P. J., Hilbers, P. A. J. & Nicolaij, K., 2010, In : Magnetic Resonance in Medicine. 63, 1, p. 257-261

Research output: Contribution to journalArticleAcademicpeer-review

27 Citations (Scopus)

An MR-compatible device for the in situ assessment of isometric contractile performance of mouse hind-limb ankle flexors.

Drost, M. R., Heemskerk, A. M., Strijkers, G. J., Dekkers, E. C. A., Kranenburg, van, G. & Nicolaij, K., 2003, In : Pflügers Archiv : European Journal of Physiology. 447, 3, p. 371-375

Research output: Contribution to journalArticleAcademicpeer-review

6 Citations (Scopus)
6 Downloads (Pure)

Annealing of proton-damaged GaAs and 1/f noise

Chen, X. Y. & Folter, de, L. C., 1997, In : Semiconductor Science and Technology. 12, 10, p. 1195-1201 7 p.

Research output: Contribution to journalArticleAcademicpeer-review

13 Citations (Scopus)

Annexin A5-conjugated quantum dots with a paramagnetic lipidic coating for the multimodal detection of apoptotic cells

Tilborg, van, G. A. F., Mulder, W. J. M., Chin, P. T. K., Storm, G., Reutelingsperger, C. P. M., Nicolay, K. & Strijkers, G. J., 2006, In : Bioconjugate Chemistry. 17, 4, p. 865-868

Research output: Contribution to journalArticleAcademicpeer-review

140 Citations (Scopus)

Annexin A5-functionalized bimodal nanoparticles for MRI and fluorescence imaging of atherosclerotic plaques

van Tilborg, G. A. F., Vucic, E., Strijkers, G. J., Cormode, D. P., Mani, V., Skajaa, T., Reutelingsperger, C. P. M., Fayad, Z. A., Mulder, W. J. M. & Nicolay, K., Oct 2010, In : Bioconjugate Chemistry. 21, 10, p. 1794-1803

Research output: Contribution to journalArticleAcademicpeer-review

85 Citations (Scopus)
1 Downloads (Pure)

Anodic plasma chemical treatment of titanium Schanz screws reduces pin loosening

Neuhoff, D., Thompson, R. E., Frauchiger, V. M., Ganser, A., Steiner, A. & Ito, K., 2005, In : Journal of Orthopaedic Trauma. 19, 8, p. 543-550

Research output: Contribution to journalArticleAcademicpeer-review

7 Citations (Scopus)

An on-bead assay for the identification of non-natural peptides targeting the Androgen Receptor–cofactor interaction

Göksel, H., Wasserberg, D., Möcklinghoff, S., Vaz Araujo, B. & Brunsveld, L., 2011, In : Bioorganic & Medicinal Chemistry. 19, 1, p. 306-311

Research output: Contribution to journalArticleAcademicpeer-review

4 Citations (Scopus)
4 Downloads (Pure)

A non-invasive method for bladder electromyography in humans

Kinder, M. V., Waalwijk van Doorn, van, E. S. C., Gommer, E. D. & Janknegt, R. A., 1998, In : Archives of Physiology and Biochemistry. 106, 1, p. 2-11

Research output: Contribution to journalArticlePopular

7 Citations (Scopus)

A noninvasive method to estimate arterial impedance by means of assessment of local diameter change and the local center-line blood flow velocity using ultrasound

Brands, P. J., Hoeks, A. P. G., Rutten, M. C. M. & Reneman, R. S., 1996, In : Ultrasound in Medicine and Biology. 22, 7, p. 895-905

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
33 Citations (Scopus)
125 Downloads (Pure)

A non-linear finite element approach for the analysis of mode-I free edge delamination in composites

Schellekens, J. C. J. & Borst, de, R., 1993, In : International Journal of Solids and Structures. 30, 9, p. 1239-1253

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
141 Citations (Scopus)
217 Downloads (Pure)

An open benchmark challenge for motion correction of myocardial perfusion MRI

Pontre, B., Cowan, B. R., DiBella, E., Kulaseharan, S., Likhite, D., Noorman, N., Tautz, L., Tustison, N., Wollny, G., Young, A. A. & Suinesiaputra, A., 1 Sep 2017, In : IEEE Journal of Biomedical and Health Informatics. 21, 5, p. 1315-1326 12 p., 7542127.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
6 Citations (Scopus)
70 Downloads (Pure)

An optical sensor based on a photonic polymer film to detect calcium in serum

Moirangthem, M., Arts, R., Merkx, M. & Schenning, A. P. H. J., 23 Feb 2016, In : Advanced Functional Materials. 26, 8, p. 1154-1160 7 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
55 Citations (Scopus)
218 Downloads (Pure)

An optimised small-molecule stabiliser of the 14-3-3-PMA2 protein-protein interaction

Richter, A., Rose, R., Hedberg, C., Waldmann, H. & Ottmann, C., 2012, In : Chemistry : A European Journal. 18, 21, p. 6520-6527 8 p.

Research output: Contribution to journalArticleAcademicpeer-review

26 Citations (Scopus)
2 Downloads (Pure)

A note on BRST quantization of SU(2) Yang-Mils mechanics

Fuster, A. & Holten, van, J. W., 2005, In : Journal of Mathematical Physics. 46, 10, 12 p., 102303.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
1 Citation (Scopus)
48 Downloads (Pure)

A note on the calculation of consistent tangent operators for von Mises and Drucker-Prager plasticity

Borst, de, R. & Groen, A. E., 1994, In : Communications in Numerical Methods in Engineering. 10, p. 1021-1025 5 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
6 Citations (Scopus)
52 Downloads (Pure)

A novel angiographic quantification of aortic regurgitation after TAVR provides an accurate estimation of regurgitation fraction derived from cardiac magnetic resonance imaging

Abdel-Wahab, M., Abdelghani, M., Miyazaki, Y., Holy, E. W., Merten, C., Zachow, D., Tonino, W. A. L., Rutten, M. C. M., van de Vosse, F. N., Morel, M. A., Onuma, Y., Serruys, P. W., Richardt, G. & Soliman, O. I., 12 Feb 2018, In : JACC: Cardiovascular Interventions. 11, 3, p. 287-297 11 p.

Research output: Contribution to journalArticleAcademicpeer-review

12 Citations (Scopus)

A novel approach for blood purification: Mixed-matrix membranes combining diffusion and adsorption in one step

Tijink, M. S. L., Wester, M., Sun, J., Saris, A., Bolhuis-Versteeg, L. A. M., Saiful, S., Joles, J. A., Borneman, Z., Wessling, M. & Stamatialis, D., Jul 2012, In : Acta Biomaterialia. 8, 6, p. 2279-2287 9 p.

Research output: Contribution to journalArticleAcademicpeer-review

65 Citations (Scopus)

A novel approach to estimate trabecular bone anisotropy from stress tensors

Hazrati Marangalou, J., Ito, K. & Rietbergen, van, B., 2015, In : Biomechanics and Modeling in Mechanobiology. 14, 1, p. 39-48 10 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
21 Citations (Scopus)
187 Downloads (Pure)

A novel approach to estimate trabecular bone anisotropy using a database approach

Hazrati Marangalou, J., Ito, K., Cataldi, M., Taddei, F. & Rietbergen, van, B., 2013, In : Journal of Biomechanics. 46, 14, p. 2356-2362 7 p.

Research output: Contribution to journalArticleAcademicpeer-review

33 Citations (Scopus)
6 Downloads (Pure)

A novel approach to tracer-kinetic modeling for (macromolecular) dynamic contrast-enhanced MRI

Jacobs, I., Strijkers, G. J., Keizer, H. M., Janssen, H. M., Nicolay, K. & Schabel, M. C., 1 Mar 2016, In : Magnetic Resonance in Medicine. 75, 3, p. 1142-1153 12 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
7 Citations (Scopus)
175 Downloads (Pure)

A novel compact Ge-BGO Compton-suppression spectrometer

Voigt, de, M. J. A., Bacelar, J. C., Micek, S. L., Schotanus, P., Verhoef, B. A. W., Wintraecken, Y. J. E. & Vermeulen, P., 1995, In : Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 356, 2-3, p. 362-375 14 p.

Research output: Contribution to journalArticleAcademicpeer-review

15 Citations (Scopus)
3 Downloads (Pure)

A novel concept for scaffold-free vessel tissue engineering : self-assembly of microtissue building blocks

Kelm, J. M., Lorber, V., Snedeker, J. G., Schmidt, D., Broggini-Tenzer, A., Weisstanner, M., Odermatt, B., Driessen - Mol, A., Zund, G. & Hoerstrup, S., 2010, In : Journal of Biotechnology. 148, 1, p. 46-55

Research output: Contribution to journalArticleAcademicpeer-review

118 Citations (Scopus)

A novel diffusion-tensor MRI approach for skeletal muscle fascicle length measurements

Oudeman, J., Mazzoli, V., Marra, M. A., Nicolay, K., Maas, M., Verdonschot, N., Sprengers, A. M., Nederveen, A. J., Strijkers, G. J. & Froeling, M., 1 Dec 2016, In : Physiological Reports. 4, 24, e13012.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
11 Citations (Scopus)
54 Downloads (Pure)
7 Citations (Scopus)
3 Downloads (Pure)

A novel fibre-ensemble level constitutive model for exogenous cross-linked collagenous tissues

Sacks, M. S., Zhang, W. & Wognum, S., 6 Feb 2016, In : Interface Focus. 6, 1, 20150090.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
21 Citations (Scopus)

A novel flexible thermoelectric sensor for intravascular flow assessment

Horst, van der, A., Voort, van der, D. D., Mimoun, B. A. Z., Rutten, M. C. M., Vosse, van de, F. N. & Dekker, R., 2013, In : IEEE Sensors Journal. 13, 10, p. 3883-3891 9 p.

Research output: Contribution to journalArticleAcademicpeer-review

5 Citations (Scopus)
3 Downloads (Pure)

A novel hybrid silk-fibroin/polyurethane three-layered vascular graft: Towards in situ tissue-engineered vascular accesses for haemodialysis

van Uden, S., Vanerio, N., Catto, V., Bonandrini, B., Tironi, M., Figliuzzi, M., Remuzzi, A., Kock, L., Redaelli, A. C. L., Greco, F. G. & Riboldi, S. A., 1 Mar 2019, In : Biomedical Materials. 14, 2, p. 025007 18 p., 025007.

Research output: Contribution to journalArticleAcademicpeer-review

1 Citation (Scopus)
2 Downloads (Pure)

A novel method for visualising and quantifying through-plane skin layer deformations

Gerhardt, L. C., Schmidt, J., Sanz-Herrera, J. A., Baaijens, F. P. T., Ansari, T., Peters, G. W. M. & Oomens, C. W. J., 2012, In : Journal of the Mechanical Behavior of Biomedical Materials. 14, p. 199-207

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
29 Citations (Scopus)
140 Downloads (Pure)

A novel organ culture model to quantify collagen remodeling in tree shrew sclera

Baldivia, S., Levy, A., Hegde, S., Aper, S. J. A., Merkx, M. & Grytz, R., 1 Nov 2016, In : PLoS ONE. 11, 11, e0166644.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
8 Citations (Scopus)
84 Downloads (Pure)

A novel passive left heart platform for device testing and research

Leopaldi, A. M., Vismara, R., van Tuijl, S., Redaelli, A., van de Vosse, F. N., Fiore, G. B. & Rutten, M. C. M., 1 Apr 2015, In : Medical Engineering & Physics. 37, 4, p. 361-366 6 p.

Research output: Contribution to journalArticleAcademicpeer-review

16 Citations (Scopus)
3 Downloads (Pure)

A novel synchronised diastolic injection method to reduce contrast volume during aortography for aortic regurgitation assessment: in vitro experiment of a transcatheter heart valve model

Miyazaki, Y., Abdelghani, M., de Boer, E. S., Aben, J. P., van Sloun, M., Suchecki, T., van't Veer, M., Collet, C., Asano, T., Katagiri, Y., Tenekecioglu, E., Soliman, O. I. I., Onuma, Y., de Winter, R., Tonino, P., van de Vosse, F. N., Rutten, M. C. M. & Serruys, P. W., 20 Dec 2017, In : EuroIntervention. 13, 11, p. 1289-1296 8 p.

Research output: Contribution to journalArticleAcademicpeer-review

5 Citations (Scopus)
Open Access

An overlapping domain technique coupling spectral and finite elements for fluid flow

Verkaik, A. C., Hulsen, M. A., Bogaerds, A. C. B. & Vosse, van de, F. N., 2014, In : Computers & Fluids. 100, p. 336-346

Research output: Contribution to journalArticleAcademicpeer-review

5 Citations (Scopus)
1 Downloads (Pure)

An overlapping domain technique coupling spectral and finite elements for fluid-structure interaction

Verkaik, A. C., Hulsen, M. A., Bogaerds, A. C. B. & Vosse, van de, F. N., 21 Dec 2015, In : Computers & Fluids. 123, p. 235-245 11 p.

Research output: Contribution to journalArticleAcademicpeer-review

4 Citations (Scopus)
6 Downloads (Pure)

Anteroposterior drawer measurements in the knee using an instrumented test device

Edixhoven, P., Huiskes, H. W. J. & Graaf, de, R., 1989, In : Clinical Orthopaedics and Related Research. 247, p. 232-242

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
28 Citations (Scopus)
86 Downloads (Pure)

Anti-angiogenesis therapy can overcome endothelial cell anergy and promote leukocyte-endothelium interactions and infiltration in tumors

Dirkx, A. E., Oude Egbrink, M. G. A., Castermans, K., Schaft, van der, D. W. J., Thijssen, V. L. J. L., Dings, R. P. M., Kwee, L., Mayo, K. H., Wagstaff, J., Bouma-ter Steege, J. C. A. & Griffioen, A. W., 2006, In : The FASEB Journal. 20, 6, p. 621-630

Research output: Contribution to journalArticleAcademicpeer-review

147 Citations (Scopus)
1 Downloads (Pure)

Antibacterial effects of electrospun chitosan/poly(ethylene oxide) nanofibrous membranes loaded with chlorhexidine and silver

Song, J., Remmers, S. J. A., Shao, J., Kolwijck, E., Walboomers, X. F., Jansen, J. A., Leeuwenburgh, S. C. G. & Yang, F., Jul 2016, In : Nanomedicine: Nanotechnology, Biology, and Medicine. 12, 5, p. 1357-1364 8 p.

Research output: Contribution to journalArticleAcademicpeer-review

25 Citations (Scopus)

Antibody activation using DNA-based logic gates

Janssen, B. M. G., Rosmalen, van, M., van Beek, L. & Merkx, M., 2015, In : Angewandte Chemie - International Edition. 127, 8, p. 2560-2563

Research output: Contribution to journalArticleAcademicpeer-review

40 Citations (Scopus)
1 Downloads (Pure)

Antibody-controlled actuation of DNA-based molecular circuits

Engelen, W., Meijer, L. H. H., Somers, B., de Greef, T. F. A. & Merkx, M., 17 Feb 2017, In : Nature Communications. 8, p. 1-8 8 p., 14473.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
34 Citations (Scopus)
129 Downloads (Pure)

Antibody detection using a FRET-based protein conformational switch

Golynskiy, M. V., Rurup, W. F. & Merkx, M., 2011, In : ChemBioChem. 11, 16, p. 2264-2267

Research output: Contribution to journalArticleAcademicpeer-review

33 Citations (Scopus)

Antimicrobial peptide modification of biomaterials using supramolecular additives

Zaccaria, S., van Gaal, R. C., Riool, M., Zaat, S. A. J. & Dankers, P. Y. W., 1 Sep 2018, In : Journal of Polymer Science, Part A: Polymer Chemistry. 56, 17, p. 1926-1934 9 p.

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
4 Citations (Scopus)
37 Downloads (Pure)

Anti-tumor activity of liposomal glucocorticoids : the relevance of liposome-mediated drug delivery, intratumoral localization and systemic activity

Kluza, E., Yeo, S. Y., Schmid, S., Schaft, van der, D. W. J., Boekhoven, R. W., Storm, G., Schiffelers, R. M., Strijkers, G. J. & Nicolay, K., 2011, In : Journal of Controlled Release. 151, 1, p. 10-17 8 p.

Research output: Contribution to journalArticleAcademicpeer-review

49 Citations (Scopus)

Anti-tumor activity of the novel angiogenesis inhibitor anginex.

Dings, R. P. M., Schaft, van der, D. W. J., Hargittai, B., Haseman, J., Griffioen, A. W. & Mayo, K. H., 2003, In : Cancer Letters. 194, 1, p. 55-66

Research output: Contribution to journalArticleAcademicpeer-review

58 Citations (Scopus)

A numerical analysis of steady flow in a three-dimensional model of the carotid artery bifurcation

Rindt, C. C. M., Steenhoven, van, A. A., Janssen, J. D., Reneman, R. S. & Segal, A., 1990, In : Journal of Biomechanics. 23, 5, p. 461-473 13 p.

Research output: Contribution to journalArticleAcademicpeer-review

63 Citations (Scopus)
1 Downloads (Pure)
40 Citations (Scopus)
2 Downloads (Pure)

A numerical-experimental method for a mechanical characterization of biological materials

Oomens, C. W. J., van Ratingen, M. R., Janssen, J. D., Kok, J. J. & Hendriks, M. A. N., 1993, In : Journal of Biomechanics. 26, 4/5, p. 617-621

Research output: Contribution to journalArticleAcademicpeer-review

Open Access
File
36 Citations (Scopus)
101 Downloads (Pure)

A numerical-experimental method to characterize the non-linear mechanical behaviour of human skin

Hendriks, F. M., Brokken, D., Eemeren, van, J. T. W. M., Oomens, C. W. J., Baaijens, F. P. T. & Horsten, J. B. A. M., 2003, In : Skin Research and Technology. 9, 3, p. 274-283

Research output: Contribution to journalArticleAcademicpeer-review

216 Citations (Scopus)
3 Downloads (Pure)
14 Citations (Scopus)
Open Access
File
21 Citations (Scopus)
113 Downloads (Pure)

A numerical model of the load transmission in the tibio-femoral contact area

Huson, A., Schreppers, G-JMA. & Sauren, A. A. H. J., 1990, In : Proceedings of the Institution of Mechanical Engineers. Part H: Journal of Engineering in Medicine. 204, 1, p. 53-59

Research output: Contribution to journalArticlePopular

50 Citations (Scopus)